وصف

ISO1133-2011 ASTM D1238 Melt flow rate testing instrument

Discription:

Melt flow rate testing instrument can be used for ABS, polystyrene, polyethylene, polypropylene, polyamide, fiber resin, acrylate, POM, البلاستيك الفلور, polycarbonate and other plastic materials, the melt flow rate (MFR) or the melt volume flow rate (MVR) to be determined.

معيار:

GB/T3682-2018,ISO1133-2011, أستم D1238

 

ISO1133-2011 ASTM D1238 Melt flow rate testing instrument

شخصية المنتج:

1.English LCD Touched Screen.

2.Hand automatic cutting material.

3.Double temperature control system, temperature control precision is more accurate, higher heating efficienc

4.Double imported sensors, more accurate temperature gradient from top to bottom, can be used independently, and improve the service life.

  1. Cylinder for imports hartz alloying nitriding treatment, opening mould for carbon tungsten steel material, material reality.

6.Insulation barrels of sus304 stainless steel material for the whole, long-term high temperature does not rust.

7.Automatic calculation results, and print.

 

Test Methods:MFR Methods

Display Mode:English color touch screen display

 

ISO1133-2011 ASTM D1238 Melt flow rate testing instrument

تخصيص

نموذجLR-A001-A
Barrel parametersInner hole 9.550±0.005mm
Pistons parametersPiston head: 9.474±0.005mm
Outlet length8.000±0.025mm
ParamtersExtrusion hole 1=2.095±0.005mm
Temperature parameterWith intelligent temperature control instrument, with four pairs of significant temperature setting control, PID parameters can be automatically set, precision up to ± 0.1 degree centigrade
نطاق درجة حرارةRoom Temperature~450degree centigrade
Temperature fluctuation±0.2 ℃
توحيد درجة الحرارة±1 درجة مئوية
دقة عرض درجة الحرارة0.1درجه مئوية
Display resolution 0.1درجه مئوية
Maximum comsuption < 600دبليو
Time display resolution 0.1س
Weight parameters are as follows:
Weight accuracy ±0.5%
التكوين الأساسي

 

A 0.325kg
B 1.2kg
C 2.16kg
D 3.8kg
E 5kg
F 10kg
G 12.5kg
H 21.6kg
Position detection
Loop distance from up and down30مم
Control precision± 0.1mm
Test flow control
Times of cutting the material0~10 times
Material cutting interval0~999s(set reference Table 2)
Control flow reaches the set temperature without volatility
Barrel temperature time15 دقيقة.
Material be installed1 دقيقة.
Material sample temperature recovery time4 دقيقة.
When binder set1دقيقة
Output modeMicro-automatic print output
Cut material methodsThe hand automatic cut into one body
Test loadEight sets of weights
قوةAC220V±10% 50/60HZ