Testeur d'indice d'oxygène intelligent et automatique, contrôle par écran tactile, LR-5
- Description
- Enquête
Description
- advantages of G / D-5 intelligent automatic touch screen control oxygen index tester:
- Full-color touch screen control, just set the oxygen concentration value on the touch screen, the program will automatically adjust to the oxygen concentration balance and issue the sound of beep, eliminating the trouble of manually adjusting the oxygen concentration;
- The stepping proportional valve greatly improves the control accuracy of the flow, and the closed-loop control is adopted. Pendant le test, the oxygen concentration drift program automatically adjusts back to the target value, which avoids the disadvantage that the traditional oxygen index tester cannot adjust the oxygen concentration during the test and greatly improves the test accuracy.
II. Main technical parameters of G / D-5 intelligent automatic touch screen controlled oxygen index tester
- Utilisation d'un capteur d'oxygène importé, Concentration d'oxygène à affichage numérique sans calcul, plus précis et plus précis, gamme 0-100%
- Résolution numérique: 0.1%
- Précision de mesure: 0.1 niveau
- The touch screen setting program automatically adjusts the oxygen concentration
- One-key calibration accuracy
- One-bond ratio concentration
- Stable oxygen concentration automatic alarm sound
- With timing function
- Experimental data can be stored
- Query historical data
- Historical data can be cleared
- Optional whether to burn 50mm
- Air source fault prompt
- Oxygen sensor fault prompt
- Tips for wrong connection of oxygen and nitrogen
- Oxygen sensor aging tips
- Standard oxygen concentration input
- Diameter of combustion cylinder can be set (two common specifications are optional)
- Plage de régulation de débit: 0-20l/min (0-1200l/heure)
. 20 quartz glass tube: two specifications either (diamètre 75 ㎜ or inner diameter or greater or higher 85 ㎜)
- Débit de gaz dans le cylindre de combustion: 40mm±2mm/s
- Dimensions hors tout: 650mm * 400 * 830mm
- Précision du manomètre 2.5, résolution: 0.01mpa
- The test environment: la température ambiante: température ambiante ~ 40 ℃;, humidité relative: 70%;
- Pression d'entrée: 0.25-0.3mpa
- Pression de travail: nitrogen 0.15-0.20mpa oxygen 0.15-0.20mpa
- The specimen holder can be used for soft and hard plastics, various building materials, textile, portes coupe-feu, etc.
- Propane (butane) système de mise à feu, the ignition nozzle is made of a metal, the end has Φ 2±1 mm inner diameter nozzle, can be bent freely.Can be inserted into the combustion tube to ignite the sample, la longueur de la flamme: 16 4mm, the size of 5mm-60mm can be adjusted freely,
- Gaz: azote et oxygène à usage industriel avec une pureté de > 99%;(the purity of industrial oxygen in user-provided/normal gas stations is generally between 99.2% et 99.3%).
- Exigences de puissance: AC220 (+10%) V, 50Hz
- Maximum power: 150W
- Porte-échantillon de matériau autoportant: il peut être fixé dans la position de l'axe du cylindre de combustion et peut maintenir l'échantillon verticalement
- Porte-échantillon de matériau non autoportant: it can fix two vertical edges of the sample on the frame at the same time (optional/applicable to soft non-self-supporting materials such as textiles).
III. Design standard: GB/T 2406.2-2009
Conseils: when testing oxygen index tester, one bottle of industrial-grade oxygen/nitrogen of no less than 98% should be used as gas source. As the above gas is high-risk transport, it cannot be used as accessories of oxygen index tester, so it can only be purchased from local gas stations of users.(in order to ensure the purity of the gas, please purchase it at a local regular gas station)