Descrizione

  1. advantages of LR-5 intelligent automatic touch screen control oxygen index tester:
  2. Full-color touch screen control, just set the oxygen concentration value on the touch screen, the program will automatically adjust to the oxygen concentration balance and issue the sound of beep, eliminating the trouble of manually adjusting the oxygen concentration;
  3. The stepping proportional valve greatly improves the control accuracy of the flow, and the closed-loop control is adopted. Durante il test, the oxygen concentration drift program automatically adjusts back to the target value, which avoids the disadvantage that the traditional oxygen index tester cannot adjust the oxygen concentration during the test and greatly improves the test accuracy.

II. Main technical parameters of LR-5 intelligent automatic touch screen controlled oxygen index tester

  1. Utilizzando il sensore di ossigeno importato, concentrazione di ossigeno sul display digitale senza calcolo, più preciso e accurato, allineare 0-100%
  2. Risoluzione digitale: 0.1%
  3. Accuratezza di misurazione: 0.1 livello
  4. The touch screen setting program automatically adjusts the oxygen concentration
  5. One-key calibration accuracy
  6. One-bond ratio concentration
  7. Stable oxygen concentration automatic alarm sound
  8. With timing function
  9. Experimental data can be stored
  10. Query historical data
  11. Historical data can be cleared
  12. Optional whether to burn 50mm
  13. Air source fault prompt
  14. Oxygen sensor fault prompt
  15. Tips for wrong connection of oxygen and nitrogen
  16. Oxygen sensor aging tips
  17. Standard oxygen concentration input
  18. Diameter of combustion cylinder can be set (two common specifications are optional)
  19. Campo di regolazione del flusso: 0-20l/min (0-1200l/h)

. 20 quartz glass tube: two specifications either (diametro 75 ㎜ or inner diameter or greater or higher 85 )

  1. Portata del gas nel cilindro di combustione: 40mm±2mm/s
  2. Dimensioni complessive: 650mm * 400 * 830mm
  3. Precisione del manometro 2.5, risoluzione: 0.01mpa
  4. The test environment: la temperatura ambiente: temperatura ambiente ~ 40 ℃;, umidità relativa: 70%;
  5. Pressione in ingresso: 0.25-0.3mpa
  6. Pressione lavorativa: nitrogen 0.15-0.20mpa oxygen 0.15-0.20mpa
  7. The specimen holder can be used for soft and hard plastics, various building materials, tessili, porte tagliafuoco, eccetera
  8. Propano (butano) sistema di accensione, the ignition nozzle is made of a metal, the end has Φ 2±1 mm inner diameter nozzle, can be bent freely.Can be inserted into the combustion tube to ignite the sample, la lunghezza della fiamma: 16 4mm, the size of 5mm-60mm can be adjusted freely,
  9. Gas: azoto e ossigeno per uso industriale con purezza di > 99%;(the purity of industrial oxygen in user-provided/normal gas stations is generally between 99.2% E 99.3%).
  10. Requisiti di alimentazione: AC220 (+10%) V, 50HZ
  11. Maximum power: 150W
  12. Porta campioni di materiale autoportante: può essere fissato nella posizione dell'asse del cilindro di combustione e può sostenere il campione verticalmente
  13. Porta campioni di materiale non autoportante: it can fix two vertical edges of the sample on the frame at the same time (optional/applicable to soft non-self-supporting materials such as textiles).

III. Design standard: GB/T 2406.2-2009

Suggerimenti: when testing oxygen index tester, one bottle of industrial-grade oxygen/nitrogen of no less than 98% should be used as gas source. As the above gas is high-risk transport, it cannot be used as accessories of oxygen index tester, so it can only be purchased from local gas stations of users.(in order to ensure the purity of the gas, please purchase it at a local regular gas station)