Description

BGD 866 Small Xenon Test Chamber  

Use

Compared with adds spray function. Spray function is used to simulate rain and humidity when the material is used at outdoor. Furthermore, operator can set the cumulativeenergy (Total irradiance energy)obtained by sample to stop a testprocedure.

Operator can set all required test parameters (Irradiance, test time, BPT etc)through the touch screen, and can check its running status at any time. All running parameters can be exported tocomputer through the USB interface.

BGD 866 Small Xenon Test Chamber  

Characters

 The test procedures can be programmed freely; and up to 16 predetermined procedures can be saved in one time. Every procedure includes up to 10 segments setting data.

◆ Can set the cumulative energy (total irradiance energy)obtained by sample to finish a test procedure.

◆ With spray function, can set spray time and spray interval time.

◆ The xenon light source correspond with international standards; ensure reproducibility and comparability of testing results.

◆ Irradiance energy can be accurately controlled. The “Closed-Loop” control system can automatically compensate the change of light intensity caused by ageing or other factors.

◆ Users can easily calibrate and adjust the irradiance or the black panel temperature by themselves.

◆ With High precision Pt100 Temperature sensor. Black panel temperature is auto-controlled during the whole process

◆ Alarm function for protection:Over temperature of BPT, big error for irradiance, auto shut-down protection when opening door, protection for too low air pressure

◆ Touch screen and user-friendly operation interface allow operator to set the test parameters and monitor all the test process easily.

◆ Specimen mounting and evaluation is fast and easy With unique slide-out specimen tray

◆ Real-time data can be collected and recorded. The incidental USB connector allow users to copy the test data into a USB drive, achieving unattended operation.

Main Technical Parameters

Xenon Lamp:one 1.8KW xenon lamp (imported from America or Chinese lamp)
Fliter:Daylight filter (Also can choose extended UV filter orwindow glass filter)
Lamp Lifetime:Near 1,500 hours
Exposure Area:1,000  cm2  (can put 9 standard samples150×70mm)
Chinese lamp:30W/m2~100W/m2(300nm~400nm)or 0.3 W/m2~0.8 W/m2(@ 340nm)or 0.5 W/m2~1.5 W/m2(@ 420nm)
American lamp:50W/m2~120W/m2(300nm~400nm)or 0.3 W/m2~1.0 W/m2(@ 340nm)or 0.5 W/m2~1.8 W/m2(@ 420nm)
AdjustableBlack Board Temperature Range:RT+30℃~90℃(Depends on environment temperature and setting irradiance value)
Controllingirradiance point:340nm or 420nm or 300nm~400nm(show at the same time)
InteriorMaterial of Chamber:Stainless steel -SUS 304 material
ExteriorMaterial of Chamber:Powder coating
Overall Size:925×600×1050mm(L×W×H)
NetWeight:140KG(180KG Gross weight)

Power Supply:220V 50/60HZ;Max. Current 16A;Max.Power 2.6 KW

Ordering Information:

BGD 866/A—Small Xenon Test Chamber

BGD 8156—American Xenon Lamps (1.8 KW)

BGD 8140—Xenon Calibration Radiometer(340nm)

BGD 8141—Xenon Calibration Radiometer(420nm)

BGD 8142—Xenon Calibration Radiometer(300nm~400nm)

BGD 8170—Pure Water Machine(50L/h)






    has been added to your cart: