وصف

BGD 880-S غرفة رش الملح القابلة للبرمجة

وصف

The salt spray test is a standardized test method used to check corrosion resistance of coated samples. Coatings provide corrosion resistance to metallic parts made of steel, zamak or brass. Since coatings can provide a high corrosion resistance through the intended life of the part in use, it is necessary to check corrosion resistance by other means. اختبار رش الملح هو اختبار تآكل متسارع ينتج عنه هجوم تآكل على العينات المطلية من أجل التنبؤ بمدى ملاءمته للاستخدام كطبقة نهائية وقائية. ظهور منتجات التآكل (أكاسيد) يتم تقييمه بعد فترة من الزمن. تعتمد مدة الاختبار على مقاومة الطلاء للتآكل; كلما كان الطلاء أكثر مقاومة للتآكل, كلما طالت مدة الاختبار دون ظهور علامات التآكل.

Salt spray testing is popular because it is cheap, quick, well standardized and reasonably repeatable. There is, لكن, only a weak correlation between the duration in salt spray test and the expected life of a coating (especially on hot dip galvanized steel where drying cycles are important for durability), since corrosion is a very complicated process and can be influenced by many external factors. Nevertheless, salt spray test is widely used in the industrial sector for the evaluation of corrosion resistance of finished surfaces or parts.

The apparatus for testing consists of a closed testing chamber, where a salted solution (mainly, a solution of 5% sodium chloride) is atomized by means of a nozzle. This produces a corrosive environment of dense saline fog in the chamber so that parts exposed in it are subjected to severely corrosive conditions.

Tests performed with a standardized 5% solution of NaCL are known as NSS (neutral salt spray). Results are represented generally as testing hours in NSS without appearance of corrosion products (على سبيل المثال. 720 h in NSS according to ISO 9227). Other solutions are acetic acid (ASS test) and acetic acid with cooper chloride (CASS test), each one chosen for the evaluation of decorative coatings, such as electroplated copper-nickel-chromium, electroplated copper-nickel or anodized aluminium.

Some sources do not recommend to use ASS or CASS test cabinets interchangeably for NSS tests, as it is claimed that a thorough cleaning of the cabinet after ASS or CASS test is very difficult. ASTM does not address this issue, but ISO 9227 does not recommend it and if it is to be done, advocates a thorough cleaning.

Biuged offer various Salt Spray Cabinets from 150L capacity to customized cabinets according to different requirements. All of cainets not only can run NSS test but also CASS or ASS test

 

BGD 880-S غرفة رش الملح القابلة للبرمجة

Structure Feature
Chamber
بناء
◆Cabinets are made of imported 5mm PVC ploy plate(Nanya, Taiwan), الأعلى. durable temperature is 85 درجه مئوية

◆Cabinet sealing cover is made of European 6mm acrylic sheets

◆Salt solution reservoir equipped with water level is designe in the chamber,سهلة التنظيف

◆Humidifying tower is made of SUS 304#, endurable high pressure and good thermal insulation effect.

◆Specimen supports designed specially ensure a adjustable position angle for each specimen in order to get a uniform fog and a big specimen capacity.

◆Use water to seal working room, ensure the corrosion fog not to leak.

Electric system is separated from water system, avoid water to enter electric control box to damage accessories

◆There is a hole used to drain off fog at the back and bottom of chamber, its damater is 48mm, just used other pipe to connect this hole to drain off the fog from the working room

Chamber
Sealing Cover
V shape , the top ange is 100º, prevent condensate water during the test from dropping to specimen surface and affect testing results.
Atomizing
Tower
In order to ensure the working room to get uniform fog while spraying, this chamber use a special structure glass nozzle to atomize salt solution absolutely, then fog enter a subuliform tower installed in the working room and spray to all working room uniformly. The installation height of atomizing tower can be adjusted to control spray fog amount precisely.
Fog CollectorFog collectors are tapered funnels whose diameter are 100mm and installed in the working room.At the bottom of the funnel, there is a silicone pipe which connect with graduated cylinder installed outside. These graduated cylinders are used to monitor spray fog amount
Heating
System
For working room, heating tube is made of titanium alloy, water vapour heat the working room under the control of P.I.D
Salt Solution
Supply
The salt solution prepared well is stored in salt solution reservoir, and flow into supplying container under the water level difference. This supplying container is equipped with an automatic water leveling device which can control automatically the max. water level to keep a certain distance with spray nozzels.
Humidifying
Tower
Is made of SUS304# stainless steel, and its temperature can be set from RT-63℃ and heating up time≤60 min, can add water automatically.Water level is monitored and system would alarm once exceed set level value.
HeaterArmoured titanium alloy electric heating tube(at the bottom of working room)

Armoured SUS316# electirc heating tube(Humidifying tower)

Heating controlling methodSSR

Fog Spray System
Spray Fog
مبدأ
Use Bernouilli’s principle to absorb salt solution then atomize it

Air Compressor→Oil-water Separator(first)→Air Storage Tank→Relief Valve→Total Solenoid Valve→Oil-water Separator(second)→Saturator→Pressure Regulating Valve→Solenoid Valve for spraying→Spray Nozzle

Spray Nozzlemade of special glass, can control fog amount and spraying angle
Spray
ضغط
Spray pressure can be adjusted from 0.07MPa to 0.17 MPa, in order to make sure the spray pressure generated from spray nozzle be within the range of standard requirments, it is divided into two steps, adjust air pressure to 0.2MPa to 0.3 MPa as the first step, then adjust to 0.07MPa to 0.17 MPa under the second step
Drain away
Fog
Can drain away fog by manual or set a program to do it. Feed fresh compressed air to working room then drain away the fog of the working room quickly
Electronic Control System
مراقبE5CC digital display temperature controller imported from Omron, اليابان. control working room and humidifying tower temperature
Working
Method
Worked at fixed value, starting and stopping is timed
Setting MethodEnglish menu, input data by key
عرض
دقة
0.1℃ (temperature)
الموقتعرض رقمي , can set second, minute, 10 دقائق, ساعة, 10 ساعات , max.is 9,999 ساعات, min.is 1 ثانية
Programme
مراقب
عرض رقمي , spray time and interval time can be set freely, infinite cycle. Timing unit: ثانية, minute, 10 دقائق, ساعة, 10 hours(switch freely) max.is 9,999 ساعات, min.is 1 ثانية.
Safety Protection Device
CabinetOver temperature protection, water leakage protection
Humidifying
Tower
Over temperature protection, water leakage protection
Heating
System
Anti-dry safety protection: all heaters of the cabinet are fitted with a temperature limit protection, which can effectively solve the problem of overheating , heating tube dried , abnormal water supply, short circuit and overload etc.
إمدادات المياهWater level protector for working room, low water level protector for humidifying tower
قوةEarth leakage protection, overload and short-circuit protection

المعايير

ايزو 4611 《Plastics—Determination of the effects of exposure to damp heat, water spray and salt mist》

ايزو 7253 《 الدهانات والورنيشات — Determination of resistance to neutral salt spray (fog) 》

ايزو 9227 《Corrosion tests in artificial atmospheresSalt spray tests》

ASTM B 117 《Standard Practice for Operating Salt Spray (Fog) Apparatus》

ASTM B368 《Standard Test Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) اختبارات (CASS Test) 》

ASTM B 380 《Standard Test Method for Corrosion Testing of Decorative Electrodeposited Coatings by the Corrodkote Procedure》

ASTM G85 – 11 《Standard Practice for Modified Salt Spray (Fog) Testing》

أستم د 1735 《Standard Practice for Testing Water Resistance of Coatings Using Water Fog Apparatus》

من 50021 《Salt Spray Testing》

 

BGD 880-S غرفة رش الملح القابلة للبرمجة

حدود

Working Room Temperature RangeRT~50℃

■ Humidifying Tower Temperature RangeRT~63℃

■ Temperature Uniformity≤ ±2℃(No-load)

■ Temperature Stablility≤ ±0.5℃(No-load)

■ Temperature Devitation of Working Room±1.0℃

■ Temperature Increasing RateRT→55℃ less than 60 minutes(working room)RT→63℃ less than 60 minutes(saturated barrel)

■ Compressed Air SupplyCustomer should prepare a air compressor which can offer cleanwaterless and oilless compressed air,0.4MPa~0.8MPa pressure

طلب المعلومات →

المعلمات التقنية ↓

BGD 880/SBGD 881/SBGD 882/SBGD 883/S
Working Room Size(W×H×D),مم1000×650×720900×500×6001200×500×8001600×800×1000
Working Room Capacity(no including V shape cover)108 ل270 ل480 ل800 ل
V Shape Cover VolumeAppr. 50 لAppr. 140 لAppr. 250 لAppr. 380 ل
Overall Size(W×H×D),مم1150×1090×672 1550×1240×9001980×1350×1100 2480×1450×1250
Qua. of V Shape sample holder/pole4/66/128/1610/22
Tank capacity for Salt Solution15254045
Collectors1222
الأعلى. Sample Capacity(15cm×7cm)28 جهاز كمبيوتر شخصى70 جهاز كمبيوتر شخصى108 جهاز كمبيوتر شخصى120 جهاز كمبيوتر شخصى
Method of Opening CoverيدوييدويPneumaticPneumatic
إجمالي الطاقة2.2 كيلوواط2.2 كيلوواط 3.8 كيلوواط 3.8 كيلوواط
Salt Solution Consumption15 L/d15 L/d25 L/d25 L/d
Water for heating Consumption30 L/d30 L/d40 L/d40 L/d
Compressed Air Consumption3333
مزود الطاقة220الخامس;50/60هرتز

ياptional Accessories

BGD 1356Glass Spray Nozzle

BGD 2309CR-4 Steel Panels for Calibration of Salt Spray(Conforms ISO 3574, 20 pcs for one package)






    قد أضيفت إلى عربة التسوق:
    الدفع