Calculation of Yellowness Index and Whiteness Index Using Instrumental Color Coordinates ASTM 313-2020

Meaning and Purpose 5.1 This practice should only be used to compare specimens of the same material and of the same general appearance. For example, a series of specimens to be compared should have roughly similar luster, texture and, if not opaque, thickness and translucency. 5.2 For yellowness measurements, this practice is limited to samples with a dominant wavelength in the 570 to 580nm range or a Munsell hue of approximately 2.5GY to 2.5Y. For whiteness measurements, this practice is restricted to...

Calculation of Yellowness Index and Whiteness Index Using Instrumental Color Coordinates ASTM 313-2020

Meaning and Purpose 5.1 This practice should only be used to compare specimens of the same material and of the same general appearance. For example, a series of specimens to be compared should have roughly similar luster, texture and, if not opaque, thickness and translucency. 5.2 For yellowness measurements, this practice is limited to samples with a dominant wavelength in the 570 to 580nm range or a Munsell hue of approximately 2.5GY to 2.5Y. For whiteness measurements, this practice is restricted to...

ASTM 2244-2022 “Calculation of Color Allowable Limits and Color Differences Using Instrumental Color Coordinates”

Meaning and Purpose 5.1 The original CIE color scale based on the three stimulus values X, Y, Z and chromaticity coordinates x, y is not visually uniform. Each subsequent color scale based on CIE values applies a weighting factor to provide a degree of uniformity so that the color differences across regions of the color space will be more comparable. On the other hand, it is unlikely that the same color differences obtained for the same samples evaluated in different color...

Centrifuge type and precautions for use

A centrifuge is a commonly used laboratory equipment for separating solid particles or liquid components in a mixture. Centrifuges can be classified into various types depending on their structure and working principle. Common centrifuges include: Desktop centrifuges: Desktop centrifuges are usually smaller and suitable for small sample processing and routine laboratory work. Large capacity centrifuge: Large capacity centrifuge has a large centrifugal capacity, suitable for handling large sample volume or high-speed centrifugal separation. Microcentrifuges: Microcentrifuges are suitable for handling microsamples and usually have a...

The working principle of electrodeposition and electroplating is different

Electrodeposition and electroplating are two commonly used electrochemical surface treatment methods, and there are some differences in their working principles: How it works: Electrodeposition: Electrodeposition is the process by which metal ions are reduced from an electrolyte solution and deposited onto the surface of the workpiece to form a metal coating. In electrodeposition, the plated workpiece acts as a cathode and is connected to the negative end of the power supply, while the anode is usually an electrode in an electrolyte solution...

The working principle of electrodeposition and electroplating is different

Ultrasonic thickness measurement technology is a common coating thickness measurement method, which is used to measure the thickness of the coating. The uncertainty of the measurement result depends on a variety of factors, including the accuracy of the measuring instrument, the technical level of the operator, the characteristics of the object being measured, etc. The following are some factors that may affect the uncertainty of ultrasonic coating thickness measurement: Instrument precision: The precision of ultrasonic thickness measuring instrument is an important factor to...

The working principle of electrodeposition and electroplating is different

Electrodeposition and electroplating are two commonly used electrochemical surface treatment methods, and there are some differences in their working principles: How it works: Electrodeposition: Electrodeposition is the process by which metal ions are reduced from an electrolyte solution and deposited onto the surface of the workpiece to form a metal coating. In electrodeposition, the plated workpiece acts as a cathode and is connected to the negative end of the power supply, while the anode is usually an electrode in an electrolyte solution...

Uncertainty of ultrasonic coating thickness measurement

Ultrasonic thickness measurement technology is a common coating thickness measurement method, which is used to measure the thickness of the coating. The uncertainty of the measurement result depends on a variety of factors, including the accuracy of the measuring instrument, the technical level of the operator, the characteristics of the object being measured, etc. The following are some factors that may affect the uncertainty of ultrasonic coating thickness measurement: Instrument precision: The precision of ultrasonic thickness measuring instrument is an important factor...