ASTM D7971-2015 Standard Guide for Measuring the Roundness of Glass Spheres Using a Flow Digital Image Analyzer

ASTM D7971 Standard guidance for Measuring the roundness of glass Spheres using a Flow Digital Image Analyzer includes determining the roundness of glass spheres used in pavement marking systems using a flow digital Image analyzer. Meaning and use 4.1 The roundness of the glass beads has a significant effect on the reverse reflection efficiency of the pavement marking system. 4.2 This guide is used to characterize the roundness of glass beads for conformance testing to standard specifications for glass beads in pavement marking...

ASTM D7735-2017 “Standard Test Method for Hardness Testing with Type A Durometers for Thermoplastic Pavement Markings at High Temperatures”

Meaning and use ASTM D7735 Type A Hardness Tester for Thermoplastic Pavement Marking at High Temperatures The standard test method for hardness testing covers the Type A hardness tester for thermoplastic pavement marking materials at high temperatures. 5.1 This method is based on the penetration of a specific type of indenter when pressed into the material under specific conditions. Indentation hardness is inversely proportional to the penetration force and depends on the elastic modulus of the material, viscoelastic behavior, the geometry of...

ASTM D7681-11-2016 “Standard Test Method for Measurement of Glass Sphere Gradation with a Flow Digital Image Analyzer”

Meaning and use 5.1 The gradation (size distribution) of glass beads has a significant effect on the reverse reflection efficiency of the pavement marking system. 5.2 This test method is used to characterize the gradation (size distribution) of glass beads for compliance testing against standard specifications for glass beads in pavement marking applications. 5.3 While the potential industrial applications of this test method extend beyond the measurement of the gradation (size distribution) of glass beads for pavement marking, these are beyond the scope...

ASTM D7539-2015 Standard Practice for Humidity Regulation of Pavement Marking Coatings Test Boards Using Laboratories

ASTM D7539 Standard Practice for Humidity Regulation of Pavement Marking Coatings test Boards using a laboratory defines a standard environment with a temperature of 23±2°C, a relative humidity of 50± 5%, and no airflow for the normal regulation and testing of paints, varnishes, lacquers, and related materials. Meaning and use 5.1 The drying rate of organic coatings varies with temperature, air flow and relative humidity. In particular, the drying rate of water-based coatings depends on the evaporation of water and is therefore...

The synchronous thermal analyzer enables very accurate measurement and analysis of materials

Synchronous thermal analyzer is a high precision instrument for measuring thermal properties and thermal decomposition behavior of materials. It can analyze various types of materials, including polymers, metals, wood, textiles, etc., as well as chemical reactions, thermal expansion and other physical phenomena. It is widely used in chemistry, material science, medicine, environment and other fields. It is designed based on the principle that two or more probes perform thermal analysis tests at the same time. By measuring the heat and weight...

Determination of dispersion of carbon black for pipes

First, the definition of carbon black dispersion Carbon black is a commonly used filler, widely used in rubber, plastic, paint, ink, printing and other industrial fields. The performance of carbon black directly affects the quality and service life of the product, and the dispersion of carbon black is one of the important factors affecting the performance of carbon black. Carbon black dispersion refers to the uniform distribution of carbon black in the substrate, that is, the comprehensive performance of factors such...

Oxidation induction period analyzer is used to measure the thermal stability and oxidation stability of materials

Oxidation induction period analyzer is a common thermal analysis instrument used to measure the thermal stability and oxidation stability of materials. The OIT test method can assess the thermal degradation process of a sample by measuring its oxidation induction period at high temperatures, thus obtaining important information about the stability and durability of the material. OIT experiments typically use differential scanning calorimetry (DSC), a technique that measures the thermal degradation temperature and reaction rate of a sample under a predetermined oxygen...

The use of the plate method heat conduction instrument

The plate method thermal conductivity meter is a kind of instrument for measuring the thermal conductivity properties of substances, and it is also a commonly used experimental equipment in thermal physics research. It is to clamp the heat transfer sample between two thermal insulation plates, and apply a constant temperature difference on one of the plates, and calculate its thermal conductivity by measuring the heat conduction rate of the substance in a certain time. Its advantages are relatively simple operation,...