ASTM D5722-2014 Standard Practice for Accelerated Outdoor Weathering of Factory-Coated Embossed-Hard Fiberboard Using Concentrated Natural Sunlight and Soil-Freeze-Thawing Procedures

Meaning and use 5.1 The ability to quickly and accurately assess and predict the long-term weathering properties of plant applied coatings is important for making sound business and technical decisions. 5.2 It is important to include control samples of known field properties to determine the efficacy of the practice on specific substrates and coating systems. These control samples may include materials known to have acceptable and unacceptable field properties for the defects under consideration. 5.3 The results derived from this practice are better...

ASTM D5894-2016 Standard Practice for Salt Spray/UV Exposure in Painted Metal Cycles (Alternating Exposure in Fog/Drying Cabinets and UV/Condensing Cabinets)

ASTM D5894 also known as cyclic salt spray/UV exposure for painted metal testing. The rationale for this test is to expose the sample to alternating exposures in a fog/drying cabinet and a UV/condensing cabinet. This practice is used to paint metal samples. It uses alternating one-week cycles of cyclic corrosion and wet/dry cycles, based on ASTM G85 tests, Appendix V and fluorescent UV exposure based on ASTM G154 tests. ASTM D5894-2016 Standard Practice for Salt Spray/UV Exposure in Painted Metal Cycles...

Preparation of lead chromate alkyd antirust paint

Lead chromate alkyd anti-rust paint is a popular paint in the field of metal surface anti-corrosion, it is known for its good anti-rust properties and easy construction. The preparation method of lead chromate alkyd antirust paint and its wide application in metal surface coating will be introduced in detail in this paper. Preparation method The preparation method of lead chromate alkyd anti-rust paint includes the following key steps: Material mixing First, the pigment, filler and part of the alkyd resin are mixed, and by...

Stream hanging problem and its solution

In coating applications, flow-hanging problems can lead to poor appearance of the coating film, which can affect product quality. This article will explore the causes of streaming and solutions to help address this challenge. 1. Causes of stream suspension Flow hanging refers to the phenomenon that a part of the film flows down during the construction process, resulting in the film leaving traces on the surface or hanging vertically. Here are some common causes of a stream hang: a. Paint viscosity reduction: During...

Method for determination of dry film thickness of color coated plates

Accurate measurement of coating dry film thickness is essential for quality control and evaluation of coating properties. This paper will introduce four different methods, including magnetic thickness gauge, micrometer, metallographic microscopy and borehole failure microscopy, for the determination of coating thickness of color coated plates. Magnetic thickness gauge method Scope of application: This method is suitable for the determination of coating thickness of color coated plate such as cold rolled plate and galvanized plate, but is not suitable for the coating thickness...

How to measure the density of paint varnish with a specific gravity bottle

Coatings and varnishes are indispensable materials in a variety of applications, and their density is one of the important parameters to evaluate their quality and performance. This article will explain how to measure the density of paints and varnishes using a pycnometer, including the scope of application, the required instruments and materials, and detailed measurement steps. 1. Scope and description Density refers to the mass per unit volume of liquid at a specified temperature, usually expressed in g/ml. This method is suitable...

ASTM D6675-01-2015 Standard Practice for Salt-Accelerated Outdoor Corrosion Testing of Cosmetic Products for Organic Coatings on Automotive Steel Plates

Meaning and use 3.1 Tests of the type described in this practice may be used to assess the corrosion resistance of organic coatings to metal products exposed to high salt environments, such as areas subjected to deicing salts or coastal areas. Exposure conditions are complex and variable. Important factors include climate, time of year, presence of pollution, etc. It is often difficult, if not impossible, to precisely define or measure all the factors that influence degradation. Exposure tests need to be...

ASTM D6695-2016 Standard Practice for Xenon Arc Exposure to Coatings and Related Coatings

ASTM D6695 is the standard guide for xenon arc exposure of coatings and related coatings. This practice recommends test parameters for daylight exposure testing according to ASTM G151 and G155. ASTM D6695 Use and factors to consider As a function of their formulation and application, the coating resists performance degradation caused by exposure to light, heat and water very differently. They also respond very differently to different experimental parameters used to perform UV exposure. ASTM D6695 offers 7 different xenon arc exposure...