ASTM B490-2014 Standardpraxis für Duktilitätsmikrometer-Biegetests durch Elektroabscheidung

Bedeutung und Verwendung

4.1 Diese Vorgehensweise kann als Methode zur Kontrolle bestimmter Galvanisierungslösungen verwendet werden. It is used to indicate the presence of pollution or some other adverse condition.

4.2 Ductility measurement is of particular value when electroplated parts are subjected to moderate stresses, such as when electroplated bumpers are bolted to a car or exposed to a wide range of fluctuating temperatures (thermal shock).

ASTM B490-2014 Standardpraxis für Duktilitätsmikrometer-Biegetests durch Elektroabscheidung

Schritt 1: Umfang

1.1 This practice describes procedures for measuring the ductility of electrodeposited foils. 2

1.2 This practice is only applicable to the evaluation of electrical deposits with low ductility.

1.3 The ductility value obtained can only be considered semi-quantitative because the test has a significant operator dependence.

1.4 This practice is most applicable to internal process control, where measurements are always taken by the same operator. Changes in the ductility value can be used as an indication of possible changes in an electroplating solution.

1.5 In SI-Einheiten ausgedrückte Werte gelten als Standardwerte. In dieser Norm sind keine anderen Maßeinheiten enthalten.

1.6 Diese Norm ist nicht dazu gedacht, Sicherheitsbedenken auszuräumen, wenn überhaupt, mit seiner Verwendung verbunden. Es liegt in der Verantwortung der Benutzer dieser Norm, vor der Verwendung geeignete Sicherheits- und Gesundheitspraktiken festzulegen und die Anwendbarkeit behördlicher Beschränkungen zu bestimmen.

Teile diesen Beitrag