ASTM D 3278-2021 Bestimmung des Flammpunkts einer Flüssigkeit mit einem kleinen Gerät mit geschlossenem Tiegel

Bedeutung und Zweck
5.1 Messung des Flammpunkts Reaktion der Probe auf Hitze und Zündquelle unter kontrollierten Laborbedingungen. It is only one of many characteristics to be considered when assessing the overall flammability hazard of a material.

5.2 Flash points are used by government regulators in transportation and safety regulations to define and classify flammable and combustible materials. For a precise definition of these classes, see the specific regulations involved.

5.3 Flash points can indicate the possible presence of highly volatile and flammable impurities or contaminants in a given liquid, such as the presence of residual solvents in solvent refined dry oils.

5.4 These balanced flash point test methods use smaller specimens (2 ml) and shorter test times (1 Mindest) compared to conventional non-equilibrium test methods such as test Method D56 and Test Method D93.

5.5 Test method D3828, Test method D8174 and ISO 3679 are similar test methods and use the same equipment.

ASTM D 3278-2021 Bestimmung des Flammpunkts einer Flüssigkeit mit einem kleinen Gerät mit geschlossenem Tiegel

Geltungsbereich
1.1 These test methods include procedures to determine whether A material flashes at a specified temperature when using a small closed cup device (flash/no flash method A) or to determine the minimum finite temperature at which the material flashes (Methode B). The test method is applicable to paints, enamels, lacquers, Lack, solvents and related products with flash points between 0°C and 110°C (32°F and 230°F) and viscosity below 15 000 mm 2/ zweite (cSt) at 25 °C (77 °F).

Notiz 1: Tests can be performed at higher or lower temperatures, but the accuracy has not been determined.

Notiz 2: More viscous materials can be tested according to Appendix A4.

Notiz 3: Organic peroxides can be tested in accordance with Appendix A5, which describes the applicable safety precautions.

Notiz 4: The United States Department of Labor (OSHA, Hazard Communications), the United States Department of Transportation (RSPA) and the United States Environmental Protection Agency (EPA) have designated test method D3278 as one of several acceptable methods for determining the flash point of liquids in their regulations.

ASTM D 3278-2021 Bestimmung des Flammpunkts einer Flüssigkeit mit einem kleinen Gerät mit geschlossenem Tiegel

1.2 In SI-Einheiten ausgedrückte Werte sollten als Standardwerte betrachtet werden. The values given in parentheses following SI units are for reference only and are not considered standard values.

1.3 This standard is used to measure and describe the reaction of materials, products or components to heat and flame under controlled conditions, but does not in itself contain all the factors required for fire hazard or fire risk assessment of materials, products or components under actual fire conditions.

1.4 Diese Norm soll nicht alle Sicherheitsprobleme behandeln, wenn überhaupt, mit seiner Verwendung verbunden. Es liegt in der Verantwortung des Anwenders dieser Norm, für angemessene Sicherheit zu sorgen, Gesundheits- und Umweltpraktiken zu prüfen und vor der Verwendung die Anwendbarkeit behördlicher Beschränkungen zu ermitteln.

1.5 Dieser internationale Standard wurde in Übereinstimmung mit den international anerkannten Standardisierungsgrundsätzen entwickelt, die in der Entscheidung über Grundsätze für die Entwicklung internationaler Standards festgelegt sind, Richtlinien und Empfehlungen des Ausschusses für technische Handelshemmnisse der Welthandelsorganisation.