Beschreibung

ZXL-860 Mass Spectrometer Leak Detection Test Equipment Helium Vacuum Leak Detector
Helium Mass Spectrometer Leak Detector introduction

1.Portable, easy to move

2.Fast helium clearing function

3.Mit einer Taste kann der Leckerkennungsstatus auf Null gelöscht werden

4.High pressure resistance of leak detection port

5.Großer Erfassungsbereich

6.Englische und chinesische Menüoberfläche

7.Lange Garantie auf Kernteile.

ZXL-860 Mass Spectrometer Leak Detection Test Equipment Helium Vacuum Leak Detector
Zwei, die wichtigsten technischen Indikatoren

Minimale erkennbare LeckagerateMinimale erkennbare LeckagerateAnzeigebereich der Leckrate1×10-2 — 1×10-13Pa•m3/s
Startzeit≤3 MinutenReaktionszeit≤1,0s
Maximaler Druck des Leckerkennungsanschlusses2000PaUltimativer Druck5×10-4Pa
Saugvermögen der mechanischen Pumpe0.5L/sAnforderungen an die Stromversorgung220V, 50Hz, einzelphase, 10A
Arbeitsumfeld5-35°CRelative Luftfeuchtigkeit≤80 %
Gesamte Größe560 (W) ×420 (D) ×320 (H)Gewicht42kg

 

ZXL-860 Mass Spectrometer Leak Detection Test Equipment Helium Vacuum Leak Detector
Drei, die Hauptkonfiguration

1. German Pfa leak detector special molecular pump
2. British Edward mechanical pump
3. Built-in standard leak hole
4. Amerikanischer AD-Verstärker
5. Use a special module for mass spectrum
6. Delta LCD Touch-Farbbildschirm
7.Built-in imported Edwards vacuum pump. Ultra-low noise, low ultimate pressure, capable of continuous work for a long time.

ZXL-860 Mass Spectrometer Leak Detection Test Equipment Helium Vacuum Leak Detector
Dittaine mass spectrum leak detector features

1. Ultrahohe Empfindlichkeit. Suitable for the most demanding ammonia leak detection conditions

2. High performance mass spectrum module. Ditai Company patented productammonia mass spectrum leak detector special mass spectrum module, on the basis of learning from foreign products, independent research and development of patented products. It has been upgraded over the years. The mass spectrum module has the characteristics of ultra-high sensitivity and high stability.

3. High stability. The ion source filament in the mass spectrometry chamber adopts the design of silver wire (coated with oxidation) and presents a circular presentation inside the ion source, which is a standard oscillating ion source. It is characterized by high sensitivity and long life. It is a patented product of Di Tai Company, with unconditional three-year warranty.

4. Abundant accessories and tooling system. The company can help customers design and produce a variety of complex tooling systems. And has a wealth of accessories. Saugpistole, wireless handheld device, usw., are the company’s own patented products.

5. The core components adopt internationally famous brands. The main cooperative suppliers include Germany Pfeiffer, Germany Leibao, Britain Edward, the United States AD, Germany Baude, Japan CKD, Korea Youcheng, Britain Edward, usw.

Massenspektrometer-Leckerkennung Massenspektrometer-Leckerkennung Massenspektrometer-Leckerkennung






    wurde Ihrem Warenkorb hinzugefügt:
    Kasse