ASTM D4261-18 Standard Practice para sa Paglilinis ng Ibabaw ng kongkreto bloke para sa patong

Kahulugan at paggamit 4.1 Surface cleaning shall be applied to the preparation of masonry surfaces of concrete units for coating for light service, spatter and spill of water and chemical solutions, radiation exposure, decontamination and repeated rinsing with alkaline cleaners. ASTM D4261-18 Standard Practice for Surface Cleaning of Concrete Blocks for Coating Step 1: Saklaw 1.1 This practice includes surface cleaning of the concrete block unit prior to application of paint to remove dust, dirt, mortar spatter, oil and grease. Procedures include vacuum cleaning,...

ASTM D4262-18 Standard Test Method for Surface pH of Chemically Cleaned or Etched Concrete

Kahulugan at paggamit 3.1 Chemical cleaning and etching are used to prepare coated concrete. 3.2 Residual chemicals that are not removed by water flushing may adversely affect the properties and adhesion of coatings applied to concrete surfaces. The purpose of this test method is to determine that residual chemicals have been removed by measuring the acidity or alkalinity of the final rinsed surface. ASTM D4262-18 Standard Test Method for Surface pH of Chemically Cleaned or Etched Concrete Step 1: Saklaw 1.1 This test method includes...

ASTM D4263-18 Standard Test Method para sa pagpapasiya ng kahalumigmigan sa kongkreto sa pamamagitan ng paraan ng plastic sheet

Kahulugan at paggamit 2.1 Capillary moisture in concrete may be detrimental to the performance of some coating systems that cannot withstand moisture on or within surface boundaries. 2.2 Use this test method before coating concrete. ASTM D4263-18 Standard Test Method for the Determination of Moisture in Concrete by the Plastic Sheet Method Step 1: Saklaw 1.1 This test method is used to show the presence of capillary water in concrete. 1.2 Values in inches to pounds shall be considered as standard values. The values given in...

ASTM D4263-18 Standard Test Method para sa pagpapasiya ng kahalumigmigan sa kongkreto sa pamamagitan ng paraan ng plastic sheet

Kahulugan at paggamit 2.1 Capillary moisture in concrete may be detrimental to the performance of some coating systems that cannot withstand moisture on or within surface boundaries. 2.2 Use this test method before coating concrete. ASTM D4263-18 Standard Test Method for the Determination of Moisture in Concrete by the Plastic Sheet Method Step 1: Saklaw 1.1 This test method is used to show the presence of capillary water in concrete. 1.2 Values in inches to pounds shall be considered as standard values. The values given in...

ASTM D4285-18 Standard Test Method para sa Pagpapahiwatig ng Langis o Tubig sa Compressed Air

Kahulugan at paggamit 2.1 The compressed air needs to be cleaned to prevent contamination of the coating material and the surface on which the coating is prepared. This test method is a visual inspection technique used to determine oil or water in compressed air. Other types of contamination may require additional analytical techniques to detect. ASTM D4285-18 Standard Test Method for Indicating Oil or Water in Compressed Air Step 1: Saklaw 1.1 This test method is used to determine the presence of oil or...

ASTM D4285-18 Standard Test Method para sa Pagpapahiwatig ng Langis o Tubig sa Compressed Air

Kahulugan at Gamit 2.1 Clean compressed air is required to prevent contamination of the coating material and the surface prepared for coating. The test method is a visual inspection technique used to determine oil or water in compressed air. Other types of contamination may require additional analytical techniques for detection. ASTM D4285-18 Standard Test Method for Indicating Oil or Water in Compressed Air Scope 1.1 This test method is used to determine the presence of oil or water in compressed air used for sandblasting,...

ASTM D4286-15 Standard Practice for Determining the Qualification of Coating Contractors for Nuclear Power Generation Facilities

This practice provides a standard guide and procedural approach to assist utility owners, architects, engineers, construction personnel, and other selection agencies in determining the overall qualifications of paint contractors to perform painting work on major containment and other safety-related facilities. Hydroelectric power plant. The qualification criteria and requirements relate to the basic basic competence of the contractor to perform nuclear coating work. The assessment procedures included here are designed to fit into the detailed final qualification process. Changes in practices...

ASTM D5367-16 “Ang karaniwang kasanayan para sa Pagsusuri ng mga Coating na Inilapat sa mga Ibabaw ay ginagamot ng mga inhibitor upang maiwasan ang flash kalawang ng bakal sa tubig o tubig/abrasive sandblasting.

Kahulugan at Gamit 3.1 Paglilinis ng spray ng tubig (SSPC-TR2 / NACE 6G 198; SSPC-SP 5 (WAB)/NACE WAB-1; SSPC-SP 10 (WAB)/NACE WAB-2; SSPC-SP 6 (WAB)/NACE WAB-3; SSPC-SP 14 (WAB)/NACE WAB-8); SSPC-SP 7 (WAB)/NACE WAB-4 or not, (SSPC-SP WJ-1 / NACE WJ-1; SSPC-SP WJ-2 / NACE WJ-2; SSPC-SP WJ-3 / NACE WJ- 3; SSPC-SP WJ-4 / NACE WJ-4) abrasive, which can cause flash rust under certain environmental conditions. Inhibitors are used to prevent flash rust during drying and before coating. The inhibitor or the...