Paglalarawan

Gamitin ang

Trace moisture analyzer using a Karl Fischer coulometric titration methods, friendly na interface, 240 * 64 blue LCD display, full Chinese menu, is calculated by the instrument comes directly display the percentage of water content of the sample, the detection circuit uses advanced digital processing technology to overcome the traditional instrument temperature drift and supply voltage fluctuations interfere with the testing process, improve the accuracy and sensitivity of the test. The whole the unique free relay process design, completely eliminate the hidden dangers of memory relay contact oxidation, and extend the life of the instrument. Has been widely used in electric power, petroleum, kemikal na, pharmaceutical and other departments, I introduced one of the products of the high cost.
Mga teknikal na parameter:
Magdispley: 240 * 64 dot matrix LCD blue
Measurement Method: Karl Fischer coulometric titration
Saklaw ng pagsukat: 3μg to 100mg (1 ppm to 100%)
Sensitivity: 0.1μg
The accuracy: 3μg to 1mg ± 2μg 1mg to 100mg ± 0.2% (excluding injection error)
Clock: power down without losing the clock, year, month, date, day of the week, when, mga minuto, mga segundo
Applicable environmental temperature :0-50 ℃ applicable ambient humidity: ≤ 85%
Kapangyarihan: 30W
Mga Dimensyon: 300 * 250 * 100mm
Using the standard:
1, GB/T7600-1987in transformer oils Determination of water content (coulometry)
GB6283-1982Chemical products Determination of moisture contentKarl Fischer method (general method)
3, SH/T0246Determination of the water content of light petroleum products (power law)
4, GB/T11133-1989liquid petroleum productsDetermination of water content (Karl Fischer method)
5, GB/T7380-1995surface active agentsDetermination of water content (Karl Fischer method)
6, GB10670-1989Determination of trace water industry fluoromethanes class Karl Fischer method
7, GB10670-1989Industrial Determination of trace water fluoromethanes class
8, GB/T606-2003General method for the determination of chemical reagents moisture Karl Fischer method
9, GB/T8350-2001denatured fuel ethanol
10, GB/T3776.1-1983pesticide emulsifier Water Determination Act
11, GB/T6023-1999industrial butadiene in the determination of trace moisture Karl Fischer coulometry.
Can detect the type of material comprising:
1. Gasoline, hydraulic oil, insulating oil, transformer oil, turbine oil, anti-fuel.
2. Pentane, hexane, dimethyl butane, octane, dodecane, eicosenoic alkoxy, octacosanoic, cyclododecane, decyl cyclohexane, dimethyl butadiene, benzene, toluene, xylene, ethyl toluene, dimethyl styrene, tetradecene, petroleum ether, cyclohexylamine, methylcyclohexylamine, cycloheptane, ethylene cyclohexylamine, dicyclopentadiene, dimethylnaphthalene, trimethyl styrene, biphenyl, acenaphthene, fluorene, methylenedioxy-phenanthrene, isobutyl methyl cumene like.
3. Phenols, phenol, cresol, fluorophenol, chlorophenol, dichlorophenol, nitro phenol, atbp.
4. Ethers such as diethyl ether, diethylene glycol monomethyl ether, diethylene glycol dimethyl ether, polyethylene glycol ether, anisole, fluoroanisole, iodo anisole, didecyl ether, diheptyl ether
5. All alcohols, halogenated hydrocarbons, all lipids.

 