ASTM D5007-99-2017 “Méthode de test standard pour les changements dans le pouvoir couvrant humide-sec”

Signification et utilisation
5.1 De nombreuses peintures architecturales, surtout les peintures blanches et claires, change significantly in film opacity as they dry. Increased coverage is sometimes associated with porosity and poor film integrity in conventional formulations. The reduction can lead to disappointing paint jobs. Donc, the change in covering power from wet to dry is a property of great practical significance.

5.2 This test method can be used for paint specifications and as a brief procedure for assessment and quality control.

ASTM D5007-99-2017 “Méthode de test standard pour les changements dans le pouvoir couvrant humide-sec”

gamme
1.1 This test method includes a visual assessment of wet and dry film to determine changes in the covering power of architectural coatings during drying.

1.2 This test method is not recommended for colors other than white and light colors.

1.3 The value in SI units shall prevail. Les valeurs données entre parenthèses sont à titre indicatif uniquement.

1.4 Cette norme n'est pas destinée à traiter tous, si seulement, problèmes de sécurité associés à son utilisation. Il est de la responsabilité des utilisateurs de cette norme d'établir des pratiques de sécurité et de santé appropriées et de déterminer l'applicabilité des restrictions réglementaires avant utilisation..

1.5 Cette norme internationale est basée sur les principes de normalisation internationalement reconnus établis dans la Décision sur les principes pour l'élaboration de normes internationales., Lignes directrices et recommandations émises par le Comité des obstacles techniques au commerce de l'OMC (OTC).

Partager cette publication