Le partage des connaissances: Différence entre la viscosité cinématique et l'indice de viscosité

La viscosité cinématique est l'indice de fluidité de l'huile, quand sa valeur est plus grande, it means that its viscosity is higher, the smaller the value is, the lower the viscosity is. This number will change as the temperature changes, plus la température est élevée, the lower the viscosity will be. On the contrary, the lower the temperature, the larger the value will be, and the higher the viscosity will be.

Summary of kinematic viscosity test methods: Determine the time for a sample to flow through a viscometer of a calibrated volume at a given temperature. The product of the measured flow time and the viscometer calibration constant is the kinematic viscosity of the sample (mm²/s). According to the formula: v=C*t v is the kinematic viscosity, the unit is quadratic millimeters per second (mm²/s); C is the viscometer calibration constant, expressed in quadratic millimetres per quadratic second (mm²/s²); t indicates the process time, expressed in seconds (s).

Le partage des connaissances: Différence entre la viscosité cinématique et l'indice de viscosité

So what does the viscosity index mean? In fact, it represents the extent to which the oil changes with temperature, the higher the viscosity index, the less the oil viscosity is affected by temperature, the less the viscosity is sensitive to temperature, and the oil has been able to maintain a stable viscosity. The viscosity index can be measured by the testing equipment of the known 40℃ and 100℃ kinematic viscosity value of the oil, and then the viscosity index value is obtained according to the formula in GB/T 1995 standard.

The higher the viscosity index is, the better the viscosity temperature characteristics of the oil, and to a certain extent, the better the quality of the oil, which is an important control index in the production process of the lubricant manufacturer. According to the different viscosity index, the lubricating oil is divided into three levels: 40-80 is the intermediate viscosity index; > 80 is the high viscosity index; > 120 is a very high viscosity index; > 140 is a super high viscosity index oil.

So some customers will ask, does the higher the viscosity index of the lubricating oil mean the better the quality of the oil?

We should be clear that the viscosity index is a performance indicator of lubricating oil, not a quality indicator.

Le partage des connaissances: Différence entre la viscosité cinématique et l'indice de viscosité

The choice of lubricating oil or according to the use of conditions, not just look at the level of the viscosity index, different types of lubricating oil for the application of different surface, the corresponding viscosity index requirements will be different, and the quality of the lubricating oil itself has nothing to do with. The choice of lubricating oil is related to temperature, vitesse, load and working environment. Or according to the actual use of conditions, choose their own lubricating oil.

Par exemple: pure electric vehicle reducer oil (NB/SH/T 6042-2021) standard for the viscosity index of the quality index requirements ≥120; Heavy duty vehicle gear oil (FR 13895-2018) standard for viscosity grades 90, 110, 140 oil viscosity index quality index requirements ≥90. It can be seen that for different types of lubricating oil, it is necessary to select the appropriate lubricating oil with reference to the oil indicators specified in the corresponding national standards.

Le partage des connaissances: Différence entre la viscosité cinématique et l'indice de viscosité
The following to introduce our Shanghai Changji test kinematic viscosity equipment.

Instrument according to GB/T 265 standard

Type d'instrumentLR-265BLR-265CLR-265GLR-265H
Écart de températureRoom temperature ~100℃, lower than room temperature plus ZL.-1 cooler-70℃~ room temperatureRoom temperature ~100℃, lower than room temperature plus ZL-1 cooler
Précision du contrôle de la température±0.01 ℃±0.1 ℃±0.01 ℃
Capillary typePinnerThe options are Pinter’s, Countercurrent, and Uhl’sPinner
Nombre de trous de test2424
Timing deviceWire timingMetal button timingSecond watchTouch screen + télécommande
Caractéristiques structurellesSingle bathDouble bathDouble heating glassInside and outside double bathbody
Mode d'affichageLiquid crystal temperature control instrument8 “color HD LCD display
Calculation modeManual operationAutomatic calculation
other  Dual compressor refrigerationTape printing, data storage

Le partage des connaissances: Différence entre la viscosité cinématique et l'indice de viscosité

Conforms to SH/T0956 ASTM D7279 better than GB/T 265

Type d'instrumentG / D-0956UNG / D-0956B
Écart de températureRoom temperature ~150℃, below room temperature can be optional low temperature circulating water bath
Plage de mesure(3 – 3000)mm² / s
Entrain de mesurer le temps30 ~ 200S
Précision du contrôle de la température+ / – 0.01 °
Timing accuracy+ / – 0.01 S
Taille de l'échantillon0. 3ML~1ML
Cleaning agent dosage≤ 15 ml
Capillary typeCollapsible tube viscometer
Nombre de trous de test2
Timing deviceAuto
Calculation modeAuto
leaning methodIntégré 10.4 inch industrial computer touch screen 

External 15-inch industrial computer touch screen

Experimental agingTest in 3 minutes, clean in 3 minutes
Caractéristiques structurellesSingle bath, double tube, one temperature pointTwo baths, two tubes, two temperature points at the same time
Cleaning methodAutomatic cleaning, double solvent cleaning device
Liquid waste dischargeExterne, visual inspectionIntégré, system warning
otherAutomatic conversion of viscosity index, repetitive tolerance ratio warning, capillary coefficient calibration, temperature calibration, data transmission port, external printer, overtemperature protection and early warning, anti-dry burning protection, etc.

Comparison of kinematic viscosity test methods

Le partage des connaissances: Différence entre la viscosité cinématique et l'indice de viscosité

Executive standardSH/T 0956FR / T 265
Sample constant temperature timeNON10 à 20 minutes
Sample test time30~200S200-500S
Viscometer cleaning time≤3minAutomatic equipment: about 10min

Manual equipment: At least 30 minutes

Sample test quantity0.3~1ml20 ml
Reagent cleaning quantity≤15mlAutomatic equipment: about 100ml

Manual equipment :200~500ml

Précision du contrôle de la température0.01℃0.1 ℃
Timing accuracy0.01S0.1 deuxième
Repeatability requirement0.68%1%

 

Partager cette publication