Spectrophotomètre à réseau de paillasse YS6060
- Description
- Enquête
Description
Introduction:
Caractéristiques
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Bluetooth 2.1; Grille concave.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Plusieurs modes de mesure: Quality Management Mode, Sample Mode; Meet more users’ requirement.
10, Big capacity data storage, for 40000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Industrie des applications
YS6060 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, comme les plastiques, électronique, peinture et encre, impression, garments, cuir, papier, auto, médical, produits de beauté, nourriture, science institutes, laboratories.
Spécifications techniques
Modèle | YS6060 Benchtop Spectrophotometer |
Géométrie optique | Refléter: De:8°, de:8°(éclairage diffus, 8-angle de vision en degrés) ; SCI (composant spéculaire inclus)/SCÉ (specular component excluded) ; Include UV / excluded UV light source Transmission: De:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (composant spéculaire inclus)/SCÉ (specular component excluded) ; Include UV / excluded UV light source; Brume(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, encres, textile, garments, impression et teinture, printing etc industries for color transfer and quality control. |
Intégration de la taille de la sphère | Φ154mm |
Source de lumière | 360 nm to 780 nm, Lumière LED combinée, 400nm cut-off light source,420nmCut-off light source |
Mode spectrophotométrique | Grille concave |
Capteur | 256 Capteur d'image CMOS à double matrice d'éléments d'image |
Gamme de longueurs d'onde | 360-780nm |
Intervalle de longueur d'onde | 10nm |
Largeur de la demi-bande | 10nm |
Plage de réflectance mesurée | 0-200% |
Ouverture de mesure | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ30mm/Φ25mm; Remarque: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
Composant spéculaire | Réflectance: SCI&SCÉ / Transmission: SCI&SCÉ |
Espace colorimétrique | LABORATOIRE CIE,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Formule de différence de couleur | ΔE * un B ,ΔE * UV ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Chasseur), |
Autre indice colorimétrique | WI (ASTM E313, CIE/ISO, AATCC, Chasseur), FAIRE (ASTM D1925, ASTM 313), DE (ASTM E313, CIE/ISO), MI (Indice de métamérisme), Solidité des taches, Solidité de la couleur, Force de couleur, Opacité, 8° Brillance,Gardner Index, Pt-Co Index, 555 Index, Brume(ASTM D1003) |
Angle de l'observateur | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Données affichées | Spectrogramme/Valeurs, Échantillons de valeurs de chromaticité, Valeurs/graphique de différence de couleur, Résultat RÉUSSITE/ÉCHEC, Décalage de couleur |
Entrain de mesurer le temps | About 2.4s (Measure SCI & SCE about 5s) |
Répétabilité | Réflectance spectrale: Φ25.4mm/SCI, Écart type dans 0.04% (400 nm to 700 nm: dans 0.04%) Valeur de chromaticité:Φ25.4mm/SCI, Écart type dans ΔE*ab 0.01 ( Lorsqu'une plaque d'étalonnage blanche est mesurée 30 fois à 5 intervalles de secondes après l'étalonnage du blanc) Spectral Transmittance: Φ25.4mm/SCI, Écart type dans 0.05% (400 nm to 700 nm: dans 0.04%) Valeur de chromaticité:Φ25.4mm/SCI, Écart type dans ΔE*ab 0.02 ( Lorsqu'une plaque d'étalonnage blanche est mesurée 30 fois à 5 intervalles de secondes après l'étalonnage du blanc) |
Erreur inter-instrument | Φ25.4mm/SCI, Dans ΔE*ab 0.12 |
(Moyenne pour 12 Carreaux de couleur BCRA Série II) | |
Dimension | L*W*H=370x300x200mm |
Poids | Approx. 9.6kg |
Pouvoir | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 années, plus que 3 des mesures en millions de fois |
Afficher | 7-LCD couleur TFT en pouces, Écran tactile capacitif |
Port de données | USB & Bluetooth & Print serial port |
Stockage de données | Standard 5000 Pièces, Échantillon 40000 Pièces |
Langue | Chinois simplifié, Chinois traditionnel, Anglais, (Optional Customized German, French and Spanish) |
Environnement d'exploitation | 0~40℃, 0~85% HR (pas de condensation), Altitude < 2000m |
Environnement de stockage | -20~50℃, 0~85% HR (pas de condensation) |
Accessoire standard | Adaptateur secteur, Mode d'emploi, CD Disk(Logiciel PC), cable USB, Tableau d'étalonnage standard, Cavité d'étalonnage noire, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component |
Accessoire en option | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Remarques: | Les spécifications sont sujettes à changement sans préavis. |