Viscosimètre à écran tactile LVDV-1T/2T
- Description
- Enquête
Description
LVDV-1T/2T Touch Screen Viscometer
Caractéristiques principales:
Using ARM technology, built-in Linux system. The operation interface is simple and clear, and the viscosity test is carried out quickly and conveniently through the creation of test program and data analysis;
The viscosity measurement value is accurate: each measuring range uses the computer automatic calibration, the precision is high, the error is small;
2 Rich display: en plus de la viscosité (dynamic viscosity and kinematic viscosity), there are temperature, taux de cisaillement, contrainte de cisaillement, measured value as a percentage of full range value (graphic display), range overflow alarm, analyse automatique, the measurement range under current rotor speed combination, date, temps, etc.. The kinematic viscosity can be displayed in the case of known density to meet the different measurement requirements of users;
4 Complete function: can measure time, auto-construit 30 sets of test program, accéder 30 sets of measurement data, real-time display viscosity curve, print data and curve;
5 Front level instrument: level adjustment is intuitive and convenient;
6 régulation de vitesse en continu: RV1T series :0.3-100 tr/min ,998 tr/min
RV2T series :0.1-200 tr/min ,2000 tr/min
Show the curve of shear rate to viscosity: can set the range of shear rate, real-time display on the computer; can also
A curve showing time versus viscosity
Interface USB standard: insert U disk to copy data directly
Optional Pt100 temperature probe: temperature range from -20 to 300℃, temperature measurement accuracy 0.1℃;
10 Rich optional accessories: Viscometer dedicated thermostatic bath, thermostat cup, imprimante, échantillon de viscosité standard (huile de silicone standard)
etc.;
- Chinese and English operating system (set before leaving the factory).
the torque of the filament, the shape of the rotor, the size of the rotational speed, and the range of viscosity measurement are the same as the imported viscometer of the same type. the measured viscosity and other data are well comparable with the imported similar instruments.
Widely used in paint, peinture, produits de beauté, encre, pulpe, nourriture, huile, amidon, solvent adhesive, latex, biochemical products and other industries.
Viscosimètre à écran tactile LVDV-1T/2T
Paramètres techniques détaillés:
modèle | LVDV-1T | LVDV-2T |
Control / mode d'affichage | 5-inch color touch screen | |
vitesse(tr/min) | 0.3–100 infinitely variable speed , un total de 998 speed options | 0.1–200 infinitely variable speed , un total de 2000 speed options |
plage de mesure | Rotor 1- 4: 10-2M. mPa.s ULR: 0.6-1K Rotor 18: 3 – 10K Rotor 25: 480 – 1.60M. Rotor 31: 30 – 100K Rotor 34: 20 – 200K | Rotor 1-4: 10–6M mPa.s ULR: 0.3-6K Rotor 18: 1.5 – 300K Rotor 25: 240 – 4.8M Rotor 31: 15 – 300K Rotor 34: 30 – 600K |
rotor | L1 – L4 (Standard) Enhanced ultra-low viscosity adapter ULR (facultatif) Small sample adapters (rotors 18,25,31,34)(facultatif)) | |
Sample dosage | Rotor 1- 4: 300 – 400ml ULR: 21ml Rotor 18:7ml Rotor 25: 9ml Rotor 31: 10.5ml Rotor 34:11ml | |
K = 1000; M = 1000000 | ||
measurement erro | ±1% (Liquide newtonien) | |
erreur répétitive | ±0,5% (Liquide newtonien) | |
Show shear response / taux de cisaillement | configuration standard | |
Fonction de synchronisation | configuration standard | |
Real-time display Viscosity curve | Temperature-time curve Viscosity-time curve (The rheological curves of shear rate and viscosity can be displayed by optional data processing software) | |
viscosité cinématique | Density of samples to be entered | |
Fonction de mesure de la température | Standard temperature probe interface (optional temperature probe) | |
Automatic Scanning Function | Automatically scan and recommend the preferred combination of rotor and rotation speed | |
Maximum measurement range | Automatic display of selected combinations of rotor and rotation speed. Measurable viscosity range | |
Self-built Measuring Procedures | Jusqu'à 30 groupes (including rotor, vitesse, température, temps, etc.) | |
Preservation of measurements | Jusqu'à 30 ensembles de données (y compris la viscosité, température, rotor, vitesse, taux de cisaillement, contrainte de cisaillement, temps, densité, viscosité cinématique, etc.) | |
put a seal on | Données, curve can be printed (standard print interface, need to buy printer) | |
interface de sortie de données | USB: can insert U disk and copy data directly RS232: Connect Computer | |
thermostatic components | Selections (including various viscometer special thermostatic tank, tasse thermostatique, temperature control device, heating furnace) | |
alimentation qui fonctionne | Wide voltage operation (110 V/60 Hz or 220 V/50 Hz) | |
cote de contour | 300 × 300 × 450(mm) |