DV1T / Viscosimètre à écran tactile série DV2T
- Description
- Enquête
Description
DV1T / Viscosimètre à écran tactile série DV2T
Widely used in paint, peinture, produits de beauté, encre, pulpe, nourriture, huile, amidon, solvent adhesive, latex, biochemical products and other high viscosity industries.
Caractéristiques principales:
1 adopt ARM technology, built-in Linux system. The operation interface is simple and clear, through the creation of test program and data analysis, the viscosity test is carried out quickly and conveniently.
2.the viscosity test value is accurate : each measuring range is automatically calibrated by a computer , the precision is high , and the error is small ;
3.display is rich: en plus de la viscosité (dynamic viscosity and kinematic viscosity), there are also temperature, taux de cisaillement, contrainte de cisaillement, measurement value as a percentage of the full range value (graphic display, range overflow alarm, analyse automatique, Maximum measurement range, date, time and so on under current rotor speed combination. Show kinematic viscosity when density is known.
4.complete functions: timing measurement, auto-construit 30 groups of test programs, access to 30 groups of measurement data, real-time display of viscosity curves, printing data and curves;
5.front level: level adjustment is intuitionistic and convenient;
régulation de vitesse en continu:
6.RV1T series: 0.3-100 tr/min, un total de 998 rotational speeds
RV2T series: 0.1-200tr/min, 2000 revolutions
7.showing the curve of shear rate versus viscosity : the range of shear rate can be set , and displayed on the computer in real time ;Curve of time – à – viscosity can also be displayed
8.optional Pt100 temperature probe: large plage de température, ranging from -20 ℃ à 300 ℃, and measuring precision 0.1 ℃;
9.Optional accessories rich: R1 rotor, temperature sensor, viscometer special thermostat bath, thermostat cup, imprimante, échantillon de viscosité standard (huile de silicone standard), etc.;
The measurable range is very large, ranging from 100 à 320 million MPA.
DV1T / Viscosimètre à écran tactile série DV2T
Paramètres techniques détaillés:
modèle | RVDV-1T | HADV-1T | HBDV-1T |
Control / mode d'affichage | 5-inch color touch screen | ||
vitesse(tr/min) | 0.3–100 infinitely variable speed , un total de 998 speed options | ||
plage de mesure mPa.s | 100-13 million | 200-26 million | 800-104 million |
(Measure viscosity below the lower limit, need to choose R1 rotor) | |||
rotor | R2 – R7(6, marking) R1(Optional) | ||
Sample dosage | 500ml | ||
erreur de mesure(Liquide newtonien) | ±1% | ||
Repetition error (Liquide newtonien) | ±0,5% | ||
Display shear response / taux de cisaillement | configuration standard | ||
Fonction de synchronisation | configuration standard | ||
Display viscosity curve | taux de cisaillement – viscosity Temperature-viscosity Time-viscosity | ||
viscosité cinématique | Density of sample to be input | ||
température la mesure | Standard temperature probe interface (need to select temperature probe) | ||
autoscan | Automatically scan and recommend the best combination of rotor and speed | ||
Maximum measurement range | Automatic display of the selected combination of rotors and rotational speeds in a measurable range of viscosity | ||
Programme de mesure auto-construit | Save up to 30 groupes (including rotor, vitesse, température, temps, etc.) | ||
Preservation of measurement results | Jusqu'à 30 sets of data can be stored (y compris la viscosité, température, rotor speed, taux de cisaillement, contrainte de cisaillement, temps, densité, viscosité cinématique, etc.) | ||
imprimer | Données, curves (marked with print interface, printer to be purchased) | ||
interface de sortie de données | RS232 | ||
Composant à température constante | Selection (all kinds of viscometer special constant temperature slot, tasse à température constante) | ||
source | Wide voltage work (110V / 60Hz or 220V / 50Hz) | ||
cote de contour | 300 × 300 × 450 mm) |
modèle | RVDV-2T | HADV-2T | HBDV-2T | |
Control / mode d'affichage | 5-inch color touch screen | |||
vitesse(tr/min) | 0.1–200 infinitely variable speed , un total de 2000 speed options | |||
plage de mesure mPa.s | 100-40 million | 200-80 million | 800-320 million | |
(Measure viscosity below the lower limit, need to choose R1 rotor) | ||||
rotor | R2 – R7(6, marking) R1(Optional) | |||
Sample dosage | 500ml | |||
erreur de mesure(Liquide newtonien) | ±1% | |||
Repetition error (Liquide newtonien) | ±0,5% | |||
Display shear response / taux de cisaillement | configuration standard | |||
Fonction de synchronisation | configuration standard | |||
Display viscosity curve | taux de cisaillement – viscosity Temperature-viscosity Time-viscosity | |||
viscosité cinématique | Density of sample to be input | |||
température la mesure | Standard temperature probe interface (need to select temperature probe) | |||
autoscan | Automatically scan and recommend the best combination of rotor and speed | |||
Maximum measurement range | Automatic display of the selected combination of rotors and rotational speeds in a measurable range of viscosity | |||
Programme de mesure auto-construit | Save up to 30 groupes (including rotor, vitesse, température, temps, etc.) | |||
Preservation of measurement results | Jusqu'à 30 sets of data can be stored (y compris la viscosité, température, rotor speed, taux de cisaillement, contrainte de cisaillement, temps, densité, viscosité cinématique, etc.) | |||
imprimer | Données, curves (marked with print interface, printer to be purchased) | |||
interface de sortie de données | RS232 | |||
Composant à température constante | Selection (all kinds of viscometer special constant temperature slot, tasse à température constante) | |||
source | Wide voltage work (110V / 60Hz or 220V / 50Hz) | |||
cote de contour | 300 × 300 × 450 mm) |