Description

Spectromètre à claquage induit par laser LIBS HandHeld série X
Description du métier

In recent years, laser-induced breakdown spectroscopy (LIBS) has become the preferred tool for geochemical analysis outside the traditional laboratory environment, testing a wide range of elements. Element measurement range atomic number. =1 (including organic elements such as C, H, Ô, light elements such as N, Li, Être, B, and almost all metals and non-metals) concentration range of 10ppm to % grade (depending on the element and instrument configuration) Analysis time generally about 20s sample form solid or powder (powder needs to be measured after pressing). Laser induced breakdown spectrometer is a new analytical means in the field of spectral analysis. Its basic principle is to use a high energy laser light source to form a high intensity laser spot (plasma) on the surface of the analytical material, so that the sample is excited to emit light, which is then analyzed by the spectral system and detection system. The e technique is sensitive to most inorganic elements in the material. En même temps, it can analyze low atomic number elements such as hydrogensodium elements, which are difficult to analyze with XRF technology

Spectromètre à claquage induit par laser LIBS HandHeld série X
Paramètre du produit

Precise Elemental Analysis (LI-U)
The common handheld LIBS laser induced breakdown spectrometer (LIBS X-1688) is mainly used to test aluminum alloy, beryllium copper, carbon steel;
Specially made hand-held LIBS(LIBS X-898) for measurement of lithium in minerals, roches et saumures, pegmatite, clay and mica,

Intuitive operation
Le système d'exploitation Raspberry PI et le logiciel basé sur une application garantissent une inspection de qualité pour chaque opérateur. WIFI et Bluetooth intégrés, avec capacités GPS, permet aux utilisateurs d'imprimer, envoyer un email, et connectez-vous à presque tous les systèmes de gestion de l'information pour obtenir des rapports complets. Automatically merge XRF and LIBS test services to easily manage operations anywhere.

Conçu pour une utilisation en extérieur et en laboratoire
KMX-RAY LIBS Series Handheld Analyzer Weighing 1.65kg with Battery 2pcs (14.4v)
Écran arrière haute résolution pour une visualisation facile; Corps en métal robuste pour une durabilité maximale;
Buse conique étroite pour utilisation sur des sites de test inaccessibles;
L'argon peut être remplacé par les utilisateurs pour quelques centimes par test et des centaines de tests peuvent être effectués.
Associez-le au logiciel générateur de profils pour PC ou tablette et obtenez des fonctionnalités de bureau complètes.

Laser induced breakdown spectrometer is a new analytical means in the field of spectral analysis. Its basic principle is to use a high energy laser light source to form a high intensity laser spot (plasma) on the surface of the analytical material, so that the sample is excited to emit light, which is then analyzed by the spectral system and detection system. The e technique is sensitive to most inorganic elements in the material. It can also analyze low atomic number elements such as hydrogensodium elements, which are difficult to analyze with other techniques.

Spectromètre à claquage induit par laser LIBS HandHeld série X
LIBS HandHeld laser-induced breakdown spectroscopy has powerful technical advantages:

· Almost all natural elements can Be measured, including H, Li, Être, C, N, Ô, S and other elements that are difficult to be analyzed by conventional methods;

· The sample preparation process is very simple, and the sample surface can be cleaned or the surface coating can be removed by means of repeated pulses;

· Only a few samples (1-10g) can be used for high-throughput analysis, greatly reducing the cost of analysis;

· With ppm level detection limit and high sensitivity, detection precision and accuracy;

· Nondestructive testing in the real sense, only a tiny amount of sample is consumed, laser incident on the sample will hardly produce heating effect;

· Elemental analysis can be performed on samples in any physical state, including solid, liquide, gas and various mixtures;

· Almost unaffected by spectral interference;

· For all detectable elements, the analysis time is reduced to about 20 secondes, which has a significant advantage over other analytical techniques;

· Good environmental adaptability, almost no special requirements. Just connect the power supply can work, do not need water cooling and compressed air. Can meet the requirements of field experiment;

· Basically no periodic replacement of consumables, equipped with laser can be continuously used for more than 600,000 fois;

· Powerful analysis software and spectral database compatible with Windows operating system.

Spectromètre à claquage induit par laser LIBS HandHeld série X
LIBS HandHeld X-1688 aluminum alloy version

afficher3.5-inch resistive touch screen 320 par 480 pixels
Core technologyNo X-ray ionizing radiation based on LIBS laser technologymemoryInternal standard storage 32GB
Numéro de modèleLIBSHandheld X-1688laserClass 3B 1064nm passive solid-state laser
poids1.9 kgspectrograph<1.3nm resolution 170-1100nm spectral range
Taille (longueur * largeur * hauteur)250mm*75mm*250mmSingle test time3s
batterie14.4V,6600mAh2 batteriesHigh precision test modeThe average value of multiple single test values can be analyzed by the algorithm
WIFI24GHz802.11n/b/a wireless networkAlloy matrixAluminum matrix
BLUETOOTHBluetooth4.1Classic Low Power BluetoothTestable elementAl, B, Être, Bi, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Nb, Dans, Pb, SiSn Si, De, V, zinc, Zr, Le (residual elements)
Échantillon typeCylindrical thin sheet wire foil with diameter of 1mm or above (~0.02mm), large pieces (no powder)Température de fonctionnementStandard 0~40°C(32~100F) Recommended 5~35°C(40~95°F)
Detection lineIt varies according to different matrix and elementsRemote modeThe screen display can be projected onto a PC or mobile phone, and the test can be triggered remotely
databaseIncluding more than 100 most commonly used alloy brands available through KMAX software for advanced customizationlogicielKmax client software (application update data download, brand library custom editing, test report generation, calibration file editing, etc.)
sécuritéPhysical laser safety interlocking deviceExtended warranty serviceAn extended warranty is available by purchasing an extended warranty
Routine maintenanceClean sample room with cotton swabs Spot check with supplied alloy standard sample field calibration with specified alloy standard sample to improve accuracy

Spectromètre à claquage induit par laser LIBS HandHeld série X
LIBS HandHeld X-898 Ore Pro

technologyBased on plasma emission spectrometer technology, no Xray radiation hazardÉcran d'affichage35 inch resistive screen 320,480 pixels
Moteur principal (longueur * largeur * hauteur)250mm*75mm*270mmmemory32g
Main machine quality (y compris la batterie)1.9kgSpectrometer parameter460-690nm(670nm for Carp peak) resolution 0.2nm, imported from the Netherlands spectrometer
Battery specification14.4V, 3300mAh/47.52Wh(16.8v Rechargeable)laser100UN,14mJ.10Hz
Steam flaskSingle use of the gas bottle, 350 times dosage, purity of 99.99%Test sample typeBlock, flake, powder tablet
Transmission de donnéesWIFI, Bluetooth, USBLimite de détection0.01% – 99.99%.
Système opérateurTarte aux framboisesRoutine maintenanceUse instrument cleaning kit to clean sample room, use sample control calibration instrument to improve accuracy
Operation languageChinois, Anglais, Russian

Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X Spectromètre à claquage induit par laser LIBS HandHeld série X