LR-1452G Atomic Absorption Spectrophotometer

Description

1.Présentation du produit

The LR-1452G atomic absorption spectrophotometer uses deuterium lamp background technology to provide a reliable guarantee for quantitative analysis of elements. The multi-function window design with single interface reduces the difficulty of the analyst. The graphite furnace adopts the domestic advanced GFTV visual system to realize automatic sampling.

 

II.Champ d'application

Widely used in geology, métallurgie, médecine, industrie chimique, pétrole, agriculture, animal husbandry, ciment, printed circuit board, protection environnementale, commodity inspection and other industries.

 

III.performance characteristics

◆ Four lights, six lights, eight lights optional (optional high-performance element lights), automatic three-dimensional switching, energy balance, multi-lamp preheating at the same time to save waiting time, with deuterium lamp background and self-priming button background function;

◆ Unique integrated design of flame atomizer and graphite furnace atomizer, automatic switching and manual switching dual mode;

◆ Instrument setting conditions automatically optimize memory function, one-key scan peak search, energy balance;

◆ Data report multi-format saving and printing output, convenient data query and comparison;

◆ The instrument software adopts single-interface multi-function window design, which makes the operation simpler, real-time monitoring data changes, supports mainstream Windows operating system, supports remote control and calibration, Chinese/English version is optional, and has comprehensive quality control (QC) fonction;

◆ Advanced and reliable multiple safety protection system, automatic detection, alarme, such as insufficient pressure, fuite, flameout and other abnormal conditions;

◆ Domestic advanced graphite furnace GFTV visual system, CCD camera real-time monitoring of graphite furnace atomizer, extend the service life of graphite tube;

◆ Automatic sampler system can be realized, automatic configuration of standard curve, dilution automatique, high-precision sampling;

◆ Extendable: hydride system and combined function.

 

.Paramètre technique

Système optique
Gamme de longueurs d'onde185nm-900nm
monochromatorCzerny-Turner reinforcement
Grating engraving density1800pieces /mm
Bande passante spectraleAutomatic switching of 0nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Précision de la longueur d'onde≤±0.1nm
Wavelength repeatability≤±0.025nm
Dérive de la ligne de base0.003ABS/30min (statique) 0.005ABS/15min (dynamique)
Resolving power

 

 

Copper lamp 324.7nm wavelength, 0.2nm bandwidth, half width 0.2nm±±0.01nm
détecteurJapan Hamamatsu photomultiplier tube
Element lamp standTurret type automatic switching light frame
Flame atomization system
Limite de détection(Cu)0.006μg/mL
burner0.5mm×100mm all-titanium burner
répétabilité

 

 

RSD≤0.7%
atomizerMetal sleeve high efficiency glass sprayer
Atomizing chamberCorrosion-resistant all-plastic atomization chamber
Safety measureWith a variety of automatic safety protection functions
Position adjustmentThe optimal height and position of flame burner are automatically set
Graphite furnace atomization system
Limite de détection (CD)1.5pg
Précision ≤3%
Heating temperature rangeRoom temperature ~3000℃
Heating and temperature control modeThe power control mode in drying ashing stage and the optical maximum power mode in atomization stage are adopted
Précision du contrôle de la température1%
Taux de chauffage2000℃/S
Heating condition setting11 pas, ramp heating, ladder heating, maximum power heating, temperature monitoring and reverse measurement system
Security protectionPressure system, cooling system fault protection, power monitoring
Background correction
Deuterium lamp background correction≥60 times at 1ABS
Self-priming background correction ≥60 times at 1ABS
Traitement de l'information
Measurement methodAir-acetylene flame process, graphite furnace process
Traitement de l'informationThe linear regression method automatically fits the working curve and calculates the result automatically
Number of repeated measurements1 ~ 99 fois, repeated measurement to calculate the average, automatically give the standard deviation and relative standard deviation
Result outputMulti-format data saving and printing
Interface de CommunicationStandard RS232, USB expansion interface
Automatic sampler systemOptional 85-bit automatic sampler. Automatic configuration of standard curve, dilution automatique, high-precision sampling
Visualization systemOptional GFTV video system, graphite furnace video acquisition system
Function expansionHydride system