LR-70IPX1 2 machine d'essai de gouttes de pluie verticale
- Description
- Enquête
Description
machine d'essai de gouttes de pluie verticale
Test standards: in line with IEC60529:2001, GB4208-2017 “shell protection level (Code IP)” et GB7000.1 “Lampes Partie I; Exigences générales et tests” des provisions. But:
La fonction principale de l'équipement est de tester les propriétés physiques et autres propriétés connexes des produits électroniques et électriques., les lampes, armoires électriques, composants électriques, automobiles, motorcycles and their parts under simulated rainy weather conditions. Après l'essai, through the verification to determine whether the performance of the product meets the requirements, in order to facilitate the design, amélioration, vérification et inspection en usine du produit.
machine d'essai de gouttes de pluie verticale
Caractéristiques du produit:
1 Suitable for IPX1, IPX2 testing of products.
2 column structure, four columns can be fixed on the ground, the equipment runs smoothly, convenient packaging and transportation to save site installation time.
3 Equipment frame, sample turntable are all made of high quality aluminum alloy and SUS304# stainless steel plate, to ensure long-term use without rust.
4 drop rain board lifting: Choose high-quality electric hoist control rain board gentle lifting.
5 drop rain plate: vacuum design, made of high rust-proof stainless steel material, durable.
6 drop rain flow: The flow meter comes with regulating valve, manual accurate adjustment.
7 The rain device can be lifted automatically, and the nozzle will stop automatically when it is located at the highest point of the test object 200mm (detected by photoelectric switch).
8 Test needle: diameter 0.4mm, fully in line with the test standards; Removable, facile à remplacer.
9 Nozzle contact position brass cone design, needle can be changed without tools; A stainless steel mesh protective cover is installed under the needle to effectively prevent the test operator from accidentally touching the head of the test needle.
10 Filtration measures: The equipment is equipped with high-precision filter, which can effectively filter impurities in tap water; The filter element can be replaced regularly.
11 With compressed air drying function: Une fois le test terminé, the excess water in the drip box can be removed to avoid long-term accumulation of water scaling and plugging of pinholes.
12. The turntable motor adopts stepper motor, which can set the turntable speed directly on the touch screen; Can be precisely guaranteed! PX1 standard requirements of the turntable speed (1tr/min), and can automatically complete the IPX2 test requirements of 4 positions of 2.5 minutes of rain.
13 Control system part: Taiwan Willon 7-inch touch screen + Automate Panasonic:
IPX12 vertical rain testing machine technical parameter table: | ||||
nombre | Numéro de modèle | LR-IPX12B-800 | LR-IPX12B-1000 | |
1 | Drizzle area | 800*800mm | 1000*1000mm | |
2 | External dimension of equipment | L1000*D1000*H2300mm | L1200*D1200*H2300mm | |
3 | Diamètre du plateau tournant | ¢500mm | ¢600mm | |
4 | Drip aperture | ¢0.4 mm° | ||
5 | Distance between holes | 20*20 mm | ||
6 | In the Rain | 1-5 mm/Min (±0.5 mm/Min) | ||
7 | Flow adjustment mode | Réglage manuel | ||
8 | Drop box lifting height | 1000*1800 Ajustable | ||
9 | Turntable bearing | 50KG | ||
10 | Turntable speed | 1 tr/min | ||
11 | Turntable can be tilted | 0° or 15° | ||
12 | Lifting range of turntable | stationary | ||
13 | Temps de test | 0-999 min | ||
14 | Dispositif de protection | Electric leakage, lack of water, court-circuit | ||
15 | Source de courant (V) | 220v | ||
16 | Pouvoir (KW) | 3 | ||
17 | Répondre à la norme | CEI60529:1989+A1:1999, GB4208, GB7000.(IPX1, IPX2) |