Description

PYGCMS8900 RoHS2.0 test equipment

PYGCMS8900 is equipped with 2 injection ports, each equipped with different injector, its specific functions are as follows:

Injection port AInjection port B
Configure sample pretreatment devicePyrolyzed TP30PLUS16 position liquid injector
Main functionRapid screeningPrecise quantification
Test item16 kinds of phthalates

TOTM tri-octyl metaphenyltriate

DPHP diisodecyl phthalate

nPIP (triphenyl 3-isopropyl phosphate)

DMF (N, n-dimethylformamide)

American TSCA

Polycyclic aromatic hydrocarbons

20 brominates (polybrominated biphenyl + polybrominated diphenyl ethers)

American TSCA

Bisphenol A

Chlorinated paraffin

Identification of suspicious materials

PYGCMS8900 Double column high-end cracking phthalic acid tester Dual channel injection port RoHS2.0 tester
je. Main performance parameters of Guangzhou Golden Valley PYGCMS

1, mode de chauffage céramique avancé, corps en céramique équipé d'un capteur de température de haute précision, contrôle précis de la température, solution straw heating fast and stable fast, low electricity

Pressure work, sûr et fiable.

2, avec la fonction température programmée, vous pouvez définir différents intervalles et gradients de température;

3, Système de contrôle logiciel PC, performances d'expansion plus importantes, opération plus pratique;

4, abandonner la vanne mécanique traditionnelle, l'utilisation d'une électrovanne CNC, contrôle du trajet du gaz plus précis;

5. Coopérer avec le contrôleur de pression électronique EPC pour mieux contrôler le débit de gaz;

6, équipé d'une vanne de régulation de pression de gaz de type électronique et d'une vanne de pression à aiguille, pour obtenir un contrôle précis et complet par ordinateur; Valve switching system with independent intellectual property rights, none

Dead volume, stable et efficace, sample no residue.

7, selon les besoins des utilisateurs, différents diamètres de l'échantillon lors du traitement thermique de la paille, la température la plus élevée peut être contrôlée à 500ºC.

Le dispositif de désorption est installé directement sur l'entrée d'échantillon du chromatographe en phase gazeuse pour assurer une désorption rapide de l'échantillon dans la chromatographie..

8, peut directement au tube d'échantillonnage atmosphérique standard ou à tout matériau solide contenant une désorption de matière organique, désorption, analyse d'échantillonnage.

PYGCMS8900 Double column high-end cracking phthalic acid tester Dual channel injection port RoHS2.0 tester
paramètres techniques:

Cracking unit (Tube de fissuration Φ6) Écart de températuretempérature ambiante ~ 450ºC, with an increment of 1ºC.Cracking device (Tube de fissuration Φ6) taux de chauffage> 500ºC/min.
The cracking time range of the cracking device0.01 ~ 99,99 minutes, with an increment of 0.01 minThe purging time range of the cracker0.01 ~ 99,99 minutes, with an increment of 0.01 min
Plage de débit de purge du cracker10ml ~ 200 mlSplit flow range of the cracking unit10ml ~ 200 ml
Pyrolysis unit heating control voltage16VCCAging cleaning device temperature rangetempérature ambiante ~ 450ºC, in 1ºC increment (facultatif)
Aging cleaning device time range1 à 1200 minutes, in increments of 1 minute

PYGCMS8900 Double column high-end cracking phthalic acid tester Dual channel injection port RoHS2.0 tester
II. Main performance parameters of GCMS

Mass spectrum parameter
AMD10AMD10
Gas phase partGas phase part
Numéro de modèleA91PlusMaximum service temperature of injector450 °C
Cylinder pressure setting accuracy0.001 psiPressure range0-680kPa(0-100psi)
Furnace temperatureTempérature ambiante: +4ºC~450ºCTemperature gradient30 tiers and 31 platforms
Retention time reproducibility>0.008%Peak area reproducibility<2%RSD
Mass spectrum part
Temperament interface (transmission line)Independent temperature control maximum temperature 350ºCIon source temperature150~350 °C (inert isothermal ceramic ion source)
filament
Double filament

Quadrupole (mass analyzer)S-type prefilter * eliminates photons and neutrons and guides ions into the quadrupole without loss. Advanced design of high precision quadrupole quality filter.
Ionizing energy5ev~100eVPre-vacuum pumpMechanical pump, pumping speed 4 m3 /h
Post-stage vacuum pumpTurbo molecular pump, pumping speed 85L/sdétecteurA three-axis detector with high energy punch pole and long life electron multiplier operating at low voltage.
Mass accuracy+ / – 0.1 amuMaximum scanning speed20,000 amu/s
Mass stability±0.1amu /48hMaximum column flow6.5mL/min (He)
Carrier gas typeHelium gasSignal-to-noise ratio

(EI)

1pg octa-fluoronaphthalene (OFN) in m/z272,

Signal to noise ratio (S/N) ≥2000:1

IDL< 10fg OFN

Dynamic range>5X10^6Other Features (selected parts)The built-in UPS, a self-protection module, protects the instrument from power instability, outages, surges and spikes

Service access: Front panel of ion source is removable for cleaning and filament replacement, rear panel of detector is removable.

Modular universal circuit board design, fonction d'autodiagnostic, reduce maintenance costs.