Description

Thermal Shock Chamber/Hot Cold Temperature Shock Chamber

Champ d'application

This series of cold and heat shock test box is suitable for alternating shock test of electrical and electronic products and electronic parts.

Normes applicables

Products can meet CNS, MIL, CEI, IL, GB/T2423.5-1995, GJB150.5-87 and other standards

Control mode of cold and hot impact test chamber:

The low temperature and high temperature storage tank is used to open the valve according to the action, and the low temperature and high temperature are quickly sent to the test tank through the air supply system, so as to achieve the rapid temperature impact effect, balance the temperature control system (BTC) + specially designed air supply circulation system, P.I.D.SSR is controlled in such a way that the heat added to the system is equal to the heat loss, so that it can be used stably for a long time.

Thermal Shock Chamber/Hot Cold Temperature Shock Chamber

spécification

Temperature shock range

Haute température 60℃~+150

Basse température -55℃~-10

Preheating temperature range

60℃ ~ +180

High temperature tank heating time

RT 180℃≤35min(RT 10~+30℃).

Pre-cooling temperature range

10℃~-65

Cooling time of cryogenic tank

RT -65℃≤50min

Fluctuations de température

±1.0

Uniformité de la température

±2.0

Impact recovery time

55– 150℃≤5min.

 

Thermal Shock Chamber/Hot Cold Temperature Shock Chamber

Inner sizeW500×H400×D400 mm
Inner box materialFogged stainless steel plate(SUS#304
Outside materialSand-lined stainless steel plate(SUS#304
Matériau de conservation de la chaleura.High temperature tank: aluminum silicate insulation cotton.

b.Low temperature tank: HIGH density PU foam

Porte de la chambre

Upper and lower monolithic doors, open on the left.

UN. Embedded flat handle.

B. after button: LEUR# 304.

C. Silicone foam rubber strip.

Testing rack

UN. The load bearing shall not be more than 5KG.

B. Stainless steel SUS#304 inner case.

Heating system

Finned radiator type stainless steel electric heater.

1. High-temperature tank 6 KW.

2. Low temperature tank 3.5KW.

Air circulation system

1. 1HP×2 motors.

2. Stainless steel extension shaft.

3. SIROCCO FAN.

4. Specially designed fan forced air circulation system.

 






    a été ajouté à votre panier: