שיתוף ידע: Difference between kinematic viscosity and viscosity index

Kinematic viscosity is the fluidity index of the oil, when its value is larger, it means that its viscosity is higher, the smaller the value is, the lower the viscosity is. This number will change as the temperature changes, the higher the temperature, the lower the viscosity will be. On the contrary, the lower the temperature, the larger the value will be, and the higher the viscosity will be.

Summary of kinematic viscosity test methods: Determine the time for a sample to flow through a viscometer of a calibrated volume at a given temperature. The product of the measured flow time and the viscometer calibration constant is the kinematic viscosity of the sample (mm²/s). According to the formula: v=C*t v is the kinematic viscosity, the unit is quadratic millimeters per second (mm²/s); C is the viscometer calibration constant, expressed in quadratic millimetres per quadratic second (mm²/s²); t indicates the process time, expressed in seconds (ס).

שיתוף ידע: Difference between kinematic viscosity and viscosity index

So what does the viscosity index mean? In fact, it represents the extent to which the oil changes with temperature, the higher the viscosity index, the less the oil viscosity is affected by temperature, the less the viscosity is sensitive to temperature, and the oil has been able to maintain a stable viscosity. The viscosity index can be measured by the testing equipment of the known 40℃ and 100℃ kinematic viscosity value of the oil, and then the viscosity index value is obtained according to the formula in GB/T 1995 תֶקֶן.

The higher the viscosity index is, the better the viscosity temperature characteristics of the oil, and to a certain extent, the better the quality of the oil, which is an important control index in the production process of the lubricant manufacturer. According to the different viscosity index, the lubricating oil is divided into three levels: 40-80 is the intermediate viscosity index; > 80 is the high viscosity index; > 120 is a very high viscosity index; > 140 is a super high viscosity index oil.

So some customers will ask, does the higher the viscosity index of the lubricating oil mean the better the quality of the oil?

We should be clear that the viscosity index is a performance indicator of lubricating oil, not a quality indicator.

שיתוף ידע: Difference between kinematic viscosity and viscosity index

The choice of lubricating oil or according to the use of conditions, not just look at the level of the viscosity index, different types of lubricating oil for the application of different surface, the corresponding viscosity index requirements will be different, and the quality of the lubricating oil itself has nothing to do with. The choice of lubricating oil is related to temperature, מְהִירוּת, load and working environment. Or according to the actual use of conditions, choose their own lubricating oil.

לדוגמה: pure electric vehicle reducer oil (NB/SH/T 6042-2021) standard for the viscosity index of the quality index requirements ≥120; Heavy duty vehicle gear oil (GB 13895-2018) standard for viscosity grades 90, 110, 140 oil viscosity index quality index requirements ≥90. It can be seen that for different types of lubricating oil, it is necessary to select the appropriate lubricating oil with reference to the oil indicators specified in the corresponding national standards.

שיתוף ידע: Difference between kinematic viscosity and viscosity index
The following to introduce our Shanghai Changji test kinematic viscosity equipment.

Instrument according to GB/T 265 תֶקֶן

Instrument typeLR-265BLR-265CLR-265GLR-265H
טווח טמפרטורותRoom temperature ~100℃, lower than room temperature plus ZL.-1 cooler-70℃~ room temperatureRoom temperature ~100℃, lower than room temperature plus ZL-1 cooler
Temperature control accuracy±0.01 ℃±0.1 ℃±0.01 ℃
Capillary typePinnerThe options are Pinter’s, Countercurrent, and Uhl’sPinner
Number of test holes2424
Timing deviceWire timingMetal button timingSecond watchמסך מגע + remote control
Structural characteristicsSingle bathDouble bathDouble heating glassInside and outside double bathbody
מצב תצוגהLiquid crystal temperature control instrument8 “color HD LCD display
Calculation modeManual operationAutomatic calculation
other  Dual compressor refrigerationTape printing, אחסון נתונים

שיתוף ידע: Difference between kinematic viscosity and viscosity index

Conforms to SH/T0956 ASTM D7279 better than GB/T 265

Instrument typeLR-0956אLR-0956ב
טווח טמפרטורותRoom temperature ~150℃, below room temperature can be optional low temperature circulating water bath
טווח מדידה(3 – 3000)mm² / ס
Measuring time30 ~ 200S
Temperature control accuracy+ / – 0.01 °
Timing accuracy+ / – 0.01 ס
Sample size0. 3ML~1ML
Cleaning agent dosage≤ 15 ml
Capillary typeCollapsible tube viscometer
Number of test holes2
Timing deviceאוטומטי
Calculation modeאוטומטי
leaning methodBuilt-in 10.4 inch industrial computer touch screen 

External 15-inch industrial computer touch screen

Experimental agingTest in 3 דקות, clean in 3 דקות
Structural characteristicsSingle bath, double tube, one temperature pointTwo baths, two tubes, two temperature points at the same time
Cleaning methodAutomatic cleaning, double solvent cleaning device
Liquid waste dischargeחיצוני, visual inspectionBuilt-in, system warning
otherAutomatic conversion of viscosity index, repetitive tolerance ratio warning, capillary coefficient calibration, temperature calibration, data transmission port, external printer, overtemperature protection and early warning, anti-dry burning protection, וכו

Comparison of kinematic viscosity test methods

שיתוף ידע: Difference between kinematic viscosity and viscosity index

Executive standardSH/T 0956GB / ט 265
Sample constant temperature timeלא10 ל 20 דקות
Sample test time30~200S200-500ס
Viscometer cleaning time≤3minAutomatic equipment: about 10min

Manual equipment: At least 30 דקות

Sample test quantity0.3~1ml20 ml
Reagent cleaning quantity≤15mlAutomatic equipment: about 100ml

Manual equipment :200~500ml

Temperature control accuracy0.01℃0.1 ℃
Timing accuracy0.01ס0.1 שְׁנִיָה
Repeatability requirement0.68%1%

 