UL94 מכשיר בדיקת דליקות אנכית אופקי
- תיאור
- חֲקִירָה
תיאור
UL94 Horizontal vertical flammability test instrument is applicable to test and assess the burning characteristics of plastic material ,can do fire flammability test,vertical flammability test, and equip with gas flowmeter, adjust the flame size, simple and safe operation.This instrument can use to assess the flammability of materials or foam plastics such as V- 0, v-1, v-2, חֲצִי פֶּנסיוֹן, 5V, HF- 1, HF- 2, HBF.
UL94 Horizontal vertical flammability test instrumen Test standard
fire test UL94
GBT2408-2008: determination of plastic combustion performance and vertical method
חברת החשמל 6065-11-10 fire prevention test
UL94 Horizontal vertical flammability test instrument Technical parameters:
Contents:≥ 0.5 cubic meter, glass observation door
שָׁעוֹן עֶצֶר: the imported timer is adjustable within the range of 0 ~ 99 דקות, with a precision of plus or minus 0.1 שניות. The combustion time can be set and the combustion duration can record
Casting time: 0 ~ 99 דקות 99 seconds can set
Residual flame time: 0 ~ 99 דקות 99 seconds can set
Afterburn time: 0 ~ 99 דקות 99 seconds can set
Test gas: יותר מ 98% methane /37MJ/m3 natural gas (gas also available)
Burning Angle: 20 °, 45 °, 90 ° (0 °) is adjustable
Size parameters of the burners are: import lamp itself, nozzle Ø 9.5±0.3 mm, inner diameter nozzle effective length to 100 ± 10 מ"מ, have air conditioning
Flame height: the standard requirement adjust from 20mm to 175mm
Flow meter: adopt 105ml/min standard
תכונות מוצר: other configurations include lighting fixtures, exhaust gas installations, gas flow regulating valves, gas pressure gauges, gas pressure regulating valves, gas flow meters, gas u-type pressure gauges and sample fixtures
ספק כוח: AC 220V, 50הרץ
Character
1, the burner electric control adjustment position, automatic timing positioning, קל לתפעול.
2, equipped with highly sensitive combustible gas leakage alarm device, gas leakage automatic alarm;
3. The burner can be inching up or down, and the distance between the burner and the sample can be adjusted at will;
4, equipped with a special exhaust system, automatic exhaust gas;
5. There are two sets of sample clips for horizontal and vertical tests;
6. Switch for horizontal and vertical test to facilitate the conversion operation of horizontal test and vertical test.
Fixture
Photos for PLC controller
UL94 Horizontal vertical flammability test instrument More Photos