MFI MFR Testing Machine Perkenalan produk:

It is designed with GB/ t3682-2018, ASTM D1238, JB/T5456, ISO1133 standards, for the determination of thermoplastic melt mass flow rate (MFR) dan aliran volume leleh (MVR) instruments.To measure the mass flow rate of the melt, manual and automatic sampling is adopted, and the interval of cutting is prompted by the alarm of the computer, and the balance is weighed. measurement of melt volume flow rate is through the displacement sensor and automatic timing system, first measure the required time for the piston to move the specified distance, and then calculate the volume flow rate according to the formula.The final results of the two methods are printed out by a microprinter.

MFI MFR Testing Machine Character

Melt index instrument color touch-screen display, PLC control machine control, circuit modular, measurement data is accurate, operasinya sederhana, intuitive and clear, kinerja yang stabil dan dapat diandalkan, it is not only applicable to the high melting temperature of polycarbonate (komputer), fluorine plastic, nylon and other engineering plastics, juga dapat diterapkan pada polietilen (pe), ABS resin with lower melting temperature, seperti tes plastik, banyak digunakan dalam produksi plastik, produk plastik, petrochemical and other industries as well as universities and colleges, unit penelitian ilmiah, the commodity inspection department.

Standar Tes

MFI MFR Testing Machine conforms to GB3682;ISO1133;ASTM D 1238.ASTM D 3364.DIN53735;UNI – 5640;Jjg878-94 and other standards, and according to the JB/T5456melt flow rate meter technical conditionsstandard manufacturing.

Technical parameters of melt flow rate meter

(1) extruded material:

Mouth Φ 2.095±0.005 mm inner diameter

The length of the die is 8.000± 0.025mm

Cylinder bore Φ 9.550±0.025 mm

Drum length 152± 0.1mm

Piston rod head diameter 9.475± 0.015mm

Piston rod head length 6.350 ±0.100 mm

Quality of test load (tingkat 8)

TingkatMass kgWeightNMade up
1Tingkat0.3253.187Piston rod + weight pallet + heat shield +NO.1 weight
2Tingkat1.20011.770.325+NO.2 0.875weight
3Tingkat2.16021.180.325+NO.3 1.835weight
4Tingkat3.80037.260.325+NO.4 3.475weight
5Tingkat5.00049.030.325+NO.5 4.675weight
6Tingkat10.00098.070.325+NO.5 4.675weight+NO.6 5.000
7Tingkat12.000122.580.325+NO.5 4.675 +NO.6 5.000+NO.7 2.500
8Tingkat21.600211.820.325+NO.2 0.875 +NO.3 1.835+NO.4 3.475+NO.5 4.675+NO.6 5.000+NO.7 2.500+NO.8 2.91

The relative errors of piston rod and combined weight are no more than 0.5%

(3) time range: 0 ~ 999s

(4) the range of temperature control: 50 ~ 400 ℃

Ketepatan: + / – 0.5 ℃ resolution: 0.1 ℃

(5) piston stroke measurement range 0 ~ 50mm accuracy 0.05mm

(6) time measurement range: 0 ~ 999.99s accuracy 0.1s

(7) overall dimensions :(length width height) 550 370 600mm

(8) berat (kg) : 25kg weight of the main engine, 21.6kg

 

Memenuhi standar:

GB/T 3682 “thermoplasticsdetermination of melt mass flow rate and melt volume flow rate

ISO 1133 plastik – determination of melt mass flow rate and melt volume flow rate of thermoplastics

JB/T 5456 technical conditions for melt flow rate meter

IV. Melt flow rate measuring device features:

  1. Industrial PLC control, suitable for long working time, with stable quality and long life
  2. The heating jacket is an integral structure, with fast heating speed and high constant temperature accuracy.
  3. Comprehensive performance, suhu, waktu, displacement.To control the
  4. High-precision linear sliding resistance is adopted for displacement measurement;

Mode tampilan;Touch screen display

  1. Scraping method;Automatic, panduan

7 Metode tes: mass method (MFR), volume method (MVR)

 