LR-B010 Three Box Thermal Shock Chamber

Utilizzo

Programable thermal shock chamber price is used to test the change of material under extremely high temperature and extremely low temperature environment that continue alternation in the shortest time,Testing the chemical changes or physical damage of material caused by the thermal expansion and contraction. Testing box divided two parts, one is hightemperature region, another is low-temperatureregion, the testing sample placed on the moving basket, using unique heat storage and cool storage,the cylinder taking basket moves up and down in the hot and cold region to complete the hot and cold temperature impact testing.

LR-B010 Three Box Thermal Shock Chamber

Specifica

ModelloUN

(A~D)

B

(A~D)

C

(A~D)

D

(A~D)

E

(A~D)

F

(A~D)

Inner size: WHD(cm)40*35*3050*30*4050*40*4050*50*4060*40*5060*50*50
External size: WHD(cm)150*180*150160*175*160160*185*160160*185*170170*185*170170*195*170
Intervallo di temperatura(Test Chamber)alta temperatura:+60℃~+200℃;low temperature -10℃~-65℃(UN:-45℃;B:-55℃;C:-65℃)
Heating TimeRT~200℃ About 30min
Cooling TimeRT~-70℃ About 85min
Temperature Conversion TimeLess than 10S
Temperature Recovery TimeLess than 5min
Deviazione della temperatura±2.0℃
Temperature Fluctuation±0.5℃
MaterialeExternal material: SUS#304 Stainless steel plate

Internal material:SUS#304Stainless steel plate

Output ModeWater-cooled or air-cooled,Taikang compressor in France
ControlloreTEMI South Korea
Sistema di raffreddamentoWater-cooled or air-cooled,Taikang compressor in France
Protection devicesFuse switch, compressor overload switch, refrigerant high and low pressure

protection switch,super humidity over-temperature protection switch,

fuse, failure warning system

patrsWatching window;50mm testing hole; partition plat
EnergiaAC380V 50/60Hz Three-phase four-wire ac power
peso (kg)7507908308809501050

 

 

 