LR-STA300 Analizzatore termico integrato
- Descrizione
- Inchiesta
Descrizione
LR-STA300 Analizzatore termico integrato
The following properties of the materials are measured and studied:
DSC: fusione, cristallizzazione, phase transformation, reaction temperature and reaction heat, oxidation, eccetera
T.G: stabilità termica, decomposition, REDOX, adsorbimento e desorbimento, free water and crystal water content, composition ratio calculation, eccetera
Structural Advantages:
1. The furnace body is heated by precious metal nickel-chromium alloy wire double-row winding system, which reduces interference and is more resistant to high temperature.
2. Tray sensor, made of precious metal nickel-chromium alloy seiko, has the advantages of high temperature resistance, oxidation resistance, resistenza alla corrosione e così via.
3. The power supply and circulation heat dissipation parts are separated from the main engine to reduce the influence of heat and vibration on the micro thermal balance.
4. Open cover structure, facile da usare. It is difficult to put the sample in the upper moving furnace body, and it is easy to cause the sample rod damage.
5. The host adopts heat insulation device to isolate the heat influence of heating furnace body on the chassis and micro thermal balance.
6. The furnace body can be replaced according to customer requirements
Advantages of controller and software:
1. Independent AD acquisition circuit, sampling speed, fast processing speed, collection frequency can be set.
2. Signal acquisition circuit, which can simultaneously collect TG signal and temperature T signal.
3. USB two-way communication is adopted between the software and the instrument to fully realize remote operation. The parameters of the instrument can be set and the operation of the instrument can be stopped by computer software.
4.7-inch full color 24bit touch screen, better man-machine interface. TG calibration can be achieved on the touch screen
LR-STA300 Analizzatore termico integrato
parametri tecnici:
1. Intervallo di temperatura: room temperature ~1550 ° C
2. Risoluzione della temperatura: 0.01℃
3. Fluttuazione della temperatura: ±0,1℃
4. Velocità di riscaldamento: 0.1~100℃/min
5. Modalità di controllo della temperatura: riscaldamento, temperatura costante, raffreddamento
6 tempo a temperatura costante: 0 ~ Impostazione arbitraria di 300 minuti (can be extended 72h)
7 cooling time: ≤15min(1000℃~100℃)
8 balance measurement range: 0.1mg ~ 2G can be extended to 5G
9. Accuracy of TG: 0.01mg
10. Resolution of TG: 0.1ug
11.Gamma DSC: 0 ~ ±1000mW
12 Risoluzione DSC: 0.1UW
13. Precisione: 0.01MW
14. Modalità display: 24po' di colore, 7 “Display LCD touch-screen
15. Dispositivo per l'atmosfera: built-in gas flow meter, including two gas switching and flow size control
Atmosfera: inerte, ossidante, riducendo, statico, dinamico
16. Software: Intelligent software, T.G, DTG, TG-DSC curve data processing, export EXECL, generate PDF map, print experimental reports
17. Interfaccia dati: interfaccia USB standard
18. Alimentazione elettrica: CA 220 V 50 Hz
19 Software: temperatura, calorific value multi point correction function, to meet the different temperature section test
20 crucible type: ceramic crucible, aluminum crucible
21 Software: temperatura, calorific value multi point correction function, can meet the high and low temperature sample test