説明

E26 7006-29-3 接触性能計

IEC 60061-3 7006-29-3 American rules and Japanese rules Contact performance gauge E26 Lamp cap gauge
E26/E26d ランプキャップゲージ

商品名 :E26 ランプホルダーゲージ 技術基準 :GB 1483/ IEC 60061-3

E26 Lamp cap gauge Classification:

IEC 60061-3 7006-29-3 American rules and Japanese rules Contact performance gauge E26 Lamp cap gauge

シリアルナンバーゲージの種類ゲージ名標準図番
1E26Lamp cap pass gauge7006-29L-4
2E26Lamp cap contact performance gauge (米国ゲージ)7006-29-3
3E26Lamp cap contact performance gauge (Day gauge)7006-29-3
4E26Lamp holder Anti-accidental contact gauge (感電防止)7006-29A-2

  1. The value is for lamps fitted with E26/24 caps. For lamps fitted with E26/25 caps, dimension K is 29.3mm.
  2. The value is for lamps fitted with E26/24 caps. For lamps fitted with E26/25 caps, dimension M is 25.9mm.
  3. The gauge is shown in the test position. In the rest position the plunger shall be above plane V.
  4. Only for E26/24
参照寸法(んん)Tolerance(んん)参照寸法Tolerance
d26.52+0.0/-0.02N(4)25.4+0.02/-0.0
H14.0+0.1/-0.1バツ28.19+0.0/-0.02
K27.94(1)+0.05/-0.0Z45+0.1/-0.1
M24.43(2)+0.05/-0.0α2±30

IEC 60061-3 7006-29-3 American rules and Japanese rules Contact performance gauge E26 Lamp cap gauge
目的:

To check lamp dimensions for contact making in IEC holders.

IEC 60061-3 7006-29-3 American rules and Japanese rules Contact performance gauge E26 Lamp cap gauge
テスト :

The shape of the lamp with regard to the fit in the lampholder is assured to be correct. If the lamp can be pushed into the gauge till plane W reaches plane V or project beyond it.

For E26/24 capped lamps, when surfaces V and W are coincident, the top of the cap including any solder or conductive material, shall not extend above surface X.






    がカートに追加されました: