GC-9870 Plus リバース制御 EPC ガスクロマトグラフ

まとめ

GC-9870 Plus gas chromatograph (touch color screen) uses fully reversed-controlled EPC electronic gas path control and high precision temperature control, combined with optimized column temperature chamber and sampler, to provide an excellent performance chromatographic separation system.

GC-9870 Plus fully reverse-control EPC automatic gas chromatograph, using imported (1280X800) color touch screen setting and display, フレンドリーなインターフェース, 簡単な操作. All by microcomputer control and management, high reliability design, reflect excellent quality performance, improve the efficiency of analysis.

GC-9870 Plus リバース制御 EPC ガスクロマトグラフ
特徴

New EPC electronic gas path control, high precision valve control electronic pressure display (choose one of two)

●GC-9870 Plus integrated EPC module for accurate and stable flow and pressure control, digital control of injector and detector gas path parameters, to ensure the consistency and reproducibility of analysis results.

● According to different requirements of customers, 1-5 EPC modules can be installed at the same time to realize EPC control of 3-15 チャンネル.

● Carrier gas flow accuracy ±5%, flow repeatability ±0.35%, flow range 200ml/min. And has standardized atmospheric pressure and temperature compensation, program pressure and flow program functions.

● New EPC electronic gas path control technology, to obtain excellent retention time repeatability accuracy to provide a guarantee.

● High precision valve control adjustment, chromatography host display and computer counter-control software real-time electronic digital pressure display, to ensure the accuracy of regulation, to achieve the repeatability of the instrument.

High efficiency column box with precision temperature control and excellent temperature performance

●GC-9870 Plus chromatograph column chamber temperature stability. With high precision temperature control system, it can meet the fast and accurate constant temperature and programmed temperature control.

● Large-capacity column box is equipped with one capillary column. In special cases, two capillary columns, or two packed columns and one capillary column can be installed at the same time.

● Dynamic temperature control range from ambient temperature +4℃ to 420℃, temperature stability up to ±0.02℃. Support 20 column box temperature gradient, through the software setting can also be arbitrarily increased.

● Eight way temperature control, any overtemperature automatically cut off the power to stop heating and alarm

 

Optional high sensitivity series amplifier

● All amplification controllers of GC-9870 Plus use reverse control data, all parameters are set and modified by computer, truly realize full reverse control.

●FID amplifier uses logarithmic amplifier to improve FID sensitivity and reproducibility.

●TCD constant current control board, using constant current control mode, current up to 220mA, improve the sensitivity and stability.

GC-9870 Plus リバース制御 EPC ガスクロマトグラフ

Main technical indicators of the instrument

温度管理

温度制御範囲: 4℃~420℃ at room temperature (1℃ increment)

Temperature control object: column box, 検出器, sampler, auxiliary, a total of 6

Steps up: 20 ステップ

Upgrade rate: 0.1℃~50℃/min (0.1℃ increment)

恒温時間: 0~9999.9min (1最小増分)

Hydrogen flame ionization detector (FID)

感度: M≤2×10-12g/s Sample: n-cetane

Best test result: M≤1×10-12g/s Sample: n-cetane

Drift: ≤2×10-13 A/30min

ノイズ: ≤2×10-14 A/30min

Thermal conductivity cell detector (TCD)

感度: ≥10000mV·mL/mg Sample: トルエン. ベンゼン

ノイズ: ≤50µV

Electron capture detector (ECD)

検出限界: ≤1×10-14g/s sample gamma-666

Baseline noise: ≤50µV Linear range: ≥104

Drift: ≤80µV/30min High operating temperature: 350℃

Flame photometric detector (FPD)

検出限界: ≤5×10-13g/s (P) サンプル: メチルパラチオン

≤5×10-13g/s (S) サンプル: メチルパラチオン

Baseline noise ≤4 x 10-13 あ

Baseline drift ≤2 x 10-11 A /30min