Characteristics of network return control gas chromatograph:

  • Using the advanced 10/100m adaptive Ethernet communication interface and built-in IP protocol stack, the instrument can easily realize long-distance data transmission through Intranet and Internet of enterprises;It facilitates the erection of laboratory and simplifies the laboratory configuration and data management.
  • Low instrument internal design process of three separate connection, can connect to the local processing, unit director and supervisor, you can easily make unit director and supervisor real-time monitoring instrument is running and analysis data;
  • Low instrument equipped with built-in integration design return control chromatography workstation, get rid of the traditional data acquisition card processing, までサポート 253 sets of chromatographic work at the same time, data processing and the chromatograph, reached the domestic leading level;
  • The Modbus/TCP server built in the built-in integrated return control workstation can easily connect the analysis results to the DCS (分散制御システム), and all parameters of the real-time return control chromatograph;
  • The instrument adopts vacuum fluorescence display technology, 高い – end atmosphere and convenient interface operation.Have two operating languages in English and Chinese to meet different user needs;
  • The instrument adopts the modular structure design, the design is clear, the replacement upgrade is convenient, protects the effectiveness of the investment;It can satisfy complex sample analysis, and it can be selected with many high performance detectors, FIDなど, TCD, ECD, FPDとNPD.
  • Can realize completely abandoned the traditional mechanical valve, pointer type pressure gauge mode!EPC technology is used to control gas path and improve the automation level of gas chromatography.
  • The real gas road failure automatic protection, 圧力流量検出自動点火, automatic fire extinguishing automatic key, automatic gas path opening, reached a key start;
  • When the instrument is designed, it can easily complete the online analysis of the gas and liquid sample (with the sample parts).
  • The system is designed for automatic sampler interface, convenient for automatic sampler and future upgrade.

主な仕様

Operation display: 蛍光表示管 (using agilent technology)

Temperature control area: 6

Low operating temperature: room temperature 4 ℃~ 450 ℃, the incremental: 1 ℃, 精度: プラスかマイナス 0.1 ℃

Program heating order number: 8-16 (オプション)

Low Cheng Sheng rate: 0.1 ~ 50 ℃ / 分 (普通);0.1 ~ 80 ℃ / 分 (高速)

External events: 8 roads;補助制御出力 4

Type of sample: filling column, capillary injection sample, 六方弁ガス注入, automatic head space sampling

Number of detectors: 3 (最大);(FID, TCD, ECD, FPD, NPD)

(1) it can be controlled by high-precision valve, and the pressure, real-time digital display of the flow and the PC synchronization display are realized.(2) an EPC control system with full back control;

Work mode of EPC and EFC: 2 types;定電流モード, constant pressure mode

Work gas of EPC and EFC: 5 types;窒素, 水素, 空気, ヘリウム, アルゴン

EPC, EFC cheng sheng: 4

The control range of EPC and EFC:

プレッシャー: 0 ~ 0.6mpa;流れ 0 ~100sccmまたは 0 ~500sccm (空気)

Control accuracy of EPC and EFC: プレッシャー 0.01 KPa;The flow rate of 0.01 SCCM

Low pressure sensor: 正確さ: full range of plus or minus 2% reproducibility: < + / – 0.05 KPa temperature coefficient: < + / – 0.01 KPa / ° C range: 0 ~ 0.3 MPa or 0 ~ 0.6 MPa;

Flow sensor: 正確さ: full range of < 5% reproducibility: < + 0.5% (full range) 範囲: 0 ~500sccm

(マニュアル, 自動, needle automatic detection) オプション

Communication interface: イーサネット: IEEE802.3水素炎イオン化検出器 (FID)

検出限界: Mt is less than 3 x 10-12g/s (positive hexadecaneisooctane solution);

Baseline noise: 未満 5 x 10-14a

Baseline drift: no more than 1 x 10-13a /30min

Linear range: より大きい 106

Highest use low temperature: 450 ℃ or less thermal conductivity detector (TCD)

The sensitivity: S is greater than 10000mV. Ml/mg (positive hexadecaneisooctane solution) (amplification 1, 2, 4, 8 times optional)

Baseline noise: 未満 10 mu V

Baseline drift: no more than 30 mu v/30min

Linear range: > 104 electronic capture detector (ECD)

検出限界: no more than 1 x 10-14g/s (propane hexa6-isooctane solution)

Baseline noise: less than 0.03mV

Baseline drift: no more than 0.2mv /30min

Linear range: greater than or equal to 104

ソース: 63Ni flame photometric detector (FPD)

検出限界: (S) 未満 5 バツ 10-11 g/S;(P) is less than or equal to 1 x 10-12g/s (メチルパラチオン – anhydrous ethanol solution)

Baseline noise: less than 0.03mV

Baseline drift: no more than 0.2mv /30min

Linear range: equal to 103 (S) 102 (P) nitrogen and phosphorus detector (NPD)

The detection limit: (N) is less than or equal to 1 times 10-13g/s;(P) 未満 5 x 10-14g/s (azobenz-malathionisooctane solution)

Baseline noise: less than 0.03mV

Baseline drift: no more than 0.2mv /30min

Linear range: greater than or equal to 102 (N) 103 (P)

 

 