振動試験機は国防で広く使用されています, 航空, 航空宇宙, コミュニケーション, エレクトロニクス, 自動車, 家電, 医薬品、食品包装、その他の産業の研究室および生産ラインの製品サンプルの振動試験. このタイプの装置は、初期故障を検出するために使用されます。, 製造中に製品が受ける正弦波およびランダムな振動能力をシミュレートします, 組み立て, 輸送と使用, 耐振動性を評価する, 構造の信頼性と完全性.

Several details that should be paid attention to when using vibration testing machine:
1.The specimen must be rigidly installed on the test bench surface, otherwise it will produce resonance and waveform distortion, affecting the test effect of the specimen in the vibration process, do not disassemble, 必要であれば, please stop first.
2.The test fixture must be used correctly and fixed to avoid personnel injury and equipment damage.
3.If any abnormal phenomenon occurs during use, stop the test immediately to avoid damage to the machine.
4.Do not touch the sensor when the system is running.
5.When working, do not put magnetic or non-magnetic objects (such as watches, 等) close to the vibration generator.
6.In order to allow the power amplifier module and the platform to have sufficient cooling time, the power amplifier leakage circuit breaker must be disconnected after 7 に 10 minutes of cooling after cutting off the signal.
7.Do not turn off the control box and the microcomputer power supply before turning off the power amplifier, otherwise the impact of the club and the vibration table will cause damage.

Vibration testing machine maintenance knowledge trilogy:
1.When the vibration testing machine is running, it is necessary to add lubricant to the movement shaft inside the equipment and the wide belt required for operation, so that the equipment can be effectively operated;
2.Equipment in the identification of whether the product can withstand this vibration environment capacity, there must be technical personnel in the surrounding supervision, so as not to be tested sample slip out will destroy the smoothness of the surface of the equipment box, gear oil needs to be cleaned regularly, and every six months need to be replaced; After the end of the test, it is necessary to clean it after cooling to maintain the cleanliness of the equipment.
3.In the test work, please try not to open the test chamber door, opening at high temperature may cause burns to the operator, and opening at low temperature may cause frostbite to the staff in the early morning, and may cause the evaporator to freeze, which directly affects the refrigeration effect.