The LR-G105 infrared gas analyzer is an intelligent industrial online analyzer developed using the NDIR non-dispersive infrared principle combined with new microcomputer technology. The instrument is suitable for use in various non-explosion-proof environments and can analyze and monitor the content of total hydrocarbons, 콜로라도, CO2, CH4, and other gases from ppm levels to 99.9% 온라인.
The instrument features upper and lower limit alarms, digital and analog outputs, and customizable measurement ranges based on customer requirements and working conditions, providing cost-effective solutions.
Typical application areas
Petrochemical, steel and metallurgy, power generation, 시멘트, air separation, 화학적인, 제약, bio-fermentation, 건축 자재, 새로운 재료, 그리고 다른 산업; including but not limited to online analysis and monitoring of CO, CO2, and other gas content in combustion processes, catalytic cracking reactions, various reaction vessels, 저장 탱크, process pipelines, combustion furnaces, and exhaust gases.
장비 특징
> Dot matrix LCD display, selectable display units: %, ppm, mg/m3
> Automatic real-time recording of measurement data (≤3000 entries), recorded data displayed in list or curve format
> Arbitrarily settable control points, passive relay output, standard 4-20mA and RS485
> Rich interface options, connectable to DCS and for communication with computers
> Gas path and program design with sensor sealed protection, ensuring stable overall performance
High cost-effectiveness; the core sensor uses imported products to ensure accurate analysis results, while other components use domestic parts of comparable quality to imported products, significantly reducing the overall price compared to imported instruments.
비분산형 IR 가스 시험기 NDIR 비분산형 적외선 가스 분석기 NDIR 다성분 가스 시험기
기술 사양
| Measurable Gases | 콜로라도, CO₂, CH₄, CnHm (other gases require further discussion) |
| Analysis Principle | Non-dispersive infrared |
| 측정 범위 | ㅏ) 콜로라도: 0-2000ppm, 0-2%, 0-5%, 0-10%, 0-20%, 0-50%, 0-100%
비) CO₂: 0-2000ppm, 0-2%, 0-5%, 0-10%, 0-20%, 0-50%, 0-100% 씨) CH₄: 0-2000ppm, 0-5%, 0-20%, 0-100% |
| 정확성 | ≤±1% F.S |
| 반복성 | ≤±0.5% F.S |
| 안정 | ≤±0.5% F.S/7d |
| 응답 시간 | T90 ≤ 15 초 (depending on the principle and sampling distance) |
| 운영 환경 | 온도: -25℃~+55℃; Humidity ≤90%RH (비응결) |
| Sample Gas Pressure | 0.05 MPa ≤ Inlet pressure ≤ 0.1 MPa (outlet must be at atmospheric pressure) |
| 샘플 가스 유량 | 400±10 ml/min |
| 전원공급장치 | 220VAC±10%, 50헤르츠±5% (24V power supply requires special mention) |
| Data Logging | 3000 entries |
| 산출 | 4~20mA, passive relay, RS485; can communicate with a computer |
| 조작방법 | Button operation |
| 치수 | 270mm (여) × 134mm (시간) × 280mm (디) |
| 장착 구멍 크기 | 230mm (여) × 134mm (시간) |
| 무게 | 대략. 4킬로그램 |