Opis

ASTM D4294 DM1262 Przenośny analizator siarki EDXRF Fluorescencyjny tester siarki rentgenowskiej Maszyna do testowania siarki XRF Miernik siarki Sprzęt do testowania pierwiastków oleju S

 

DM1262 Portable EDXRF Sulfur Analyzer

 

Low detection limit (300S) (in air): 2.6 ppm.

 

Lightweight (including battery and printer): 5.2 kg.

 

Specially designed for rapid on-site testing and analysis.

 

Improved to meet the 2019 version of the GB/T 17040 standard.

 

Complies with low-sulfur testing standards for National IV automotive gasoline and diesel, as well as fuel oils for coastal and ocean-going vessels.

CharakterystykaS

 

Energy Dispersive X-Ray Fluorescence (EDXRF) technologia analizy

 

Low-background proportional counter with a thin beryllium window and secondary filters

 

X-ray source with an optimized combination of high voltage, aktualny, and target material

 

Zgodne standardy

 

GB/T 17040

 

GB 17411

 

ASTM D4294

 

Przegląd

 

Fluorescencja rentgenowska (XRF) sulfur analyzers are quantitative analysis instruments used in industries such as petroleum, węgiel, materiały budowlane, metalurgia, i górnictwo. They are primarily used to measure total sulfur (S) content in materials including petroleum and its products, węgiel, cement, i sadza. Because they employ physical analysis methods, they offer advantages such as rapid analysis, nie ma potrzeby skomplikowanej obróbki wstępnej próbki, wysoka precyzja, minimal human error, low operator labor intensity, and zero pollution; consequently, they are widely used and have largely superseded traditional chemical analysis methods.

 

The DM1262 Portable EDXRF Sulfur Analyzer (full name: DM1262 Energy Dispersive X-Ray Fluorescence Portable Sulfur Analyzer) was developed by the company based on decades of research experience in XRF analyzers and the foundation of the earlier DM1260 model (of which over 1,000 units have been sold). Like the DM1260, it utilizes EDXRF analysis technology, a miniature X-ray tube as the excitation source, a gas-filled proportional counter with a thin beryllium window, secondary filters, and a specialized optical path system. Posiada automatyczną korekcję stosunku C/H, suitability for diverse sample types, an integrated design, duża pojemność przechowywania danych, and rapid, accurate analysis.

 

The DM1262 EDXRF portable sulfur analyzer was developed as an upgraded model to meet the requirements for rapid on-site sulfur content analysis in petroleum products and to comply with the 2019 version of the GB/T 17040 standard. In addition to retaining the advantages of the original DM1260 model, the following significant improvements have been made:

 

(1) The original proportional counter was replaced with a proportional counter featuring a lower background and a thinner window. The distances and angles between the radiation source, detektor, i próbkę dostosowano, as was the thickness of the secondary filter.

 

(2) The fixed X-ray source was replaced with an adjustable X-ray source, allowing the high voltage and current to be tuned based on the sulfur content being measured. The target material of the X-ray tube was also changed.

 

(3) The original simple multi-channel pulse height analyzer was replaced with a newly designed digital multi-channel pulse height analyzer utilizing FPGA and DSP technologies; this reduced dead time, increased count throughput, and decreased both weight and volume.

 

(4) The X-ray tube and high-voltage unit were integrated into a single assembly, further reducing weight and volume.

 

(5) The original small-scale circuitry was replaced with a new large-scale integrated circuit (procesor), and vertical circuit components were replaced with surface-mount technology (SMT) składniki. A lithium-ion battery was adopted to replace the switching power supply.

 

Ulepszenia (1), (2), I (3) lowered the background noise and increased sensitivity, thereby significantly lowering the detection limit to 2.6 ppm (300S). This enables the analyzer to fully meet the PLOQ (Practical Limit of Quantitation) requirement of 16 ppm specified in the 2019 version of GB/T 17040. It also complies with the relevant requirements of the national standard GB 17411 and the US national standard ASTM D4294. Ulepszenia (3), (4), I (5) drastically reduced the weight and volume of the analyzer.

 

The DM1262 EDXRF portable sulfur analyzer is a compact and lightweight instrument, weighing approximately 5 kg (including battery and printer). It is easy to carry and requires no gas, próżnia, or sample dilution, making it particularly suitable for rapid on-site testing and analysis. The launch of the DM1262 EDXRF portable sulfur analyzer represents a significant milestone in our company’s continuous improvement, ensuring we maintain our long-standing domestic leadership in the field of X-ray fluorescence (XRF) analyzers.

 

Cechy

 

Fast and Accurate – Rapid measurement; results are typically available within tens of seconds. Offers high repeatability and reproducibility.

 

Low Detection Limit – Utilizes EDXRF technology, a low-background proportional counter with a thin beryllium window, and secondary filters to achieve a low detection limit.

 

Compact and Lightweight – Weighs only approximately 5.2 kg (including battery and printer). Operates in an ambient atmosphere without auxiliary equipment, making it ideal for rapid on-site testing.

Long Battery Life – Features ultra-low power consumption and uses a lithium-ion battery for extended continuous operation.

 

High Adaptability – Includes automatic C/H ratio correction and matrix effect correction, making it suitable for various sample types. Automatic working curve switching accommodates a wide measurement range.

 

Long-term Stability – Employs a variable-gain digital multi-channel analyzer with functions such as automatic PHA adjustment and drift correction, zapewniając doskonałą długoterminową stabilność.

 

Eco-friendly and Energy-efficient– Radiation protection meets exemption standards. Non-destructive analysis requires no sample contact, produces no pollution, and eliminates the need for chemical reagents or combustion.

 

Ease of Use – Touchscreen operation. Simply load the sample into the cup, place it in the instrument, i naciśnij [Start] button—enabling true one-touch operation.

 

High Reliability – Integrated design with high component integration; offers strong environmental adaptability, high interference resistance, and superior reliability.

 

Data Storage and Transfer – Stores massive amounts of data with power-loss protection; data can be viewed at any time and transferred to a PC.

 

Cost-effective – Requires no gas, próżnia, or dilution, co skutkuje wyjątkowo niskimi kosztami eksploatacji i konserwacji. Priced at half the cost of comparable international products.

 

Aplikacje

 

Ideally suited for rapid on-site testing and analysis of sulfur content (począwszy od 16 ppm do 4.6%) in various petroleum products—including automotive gasoline and diesel, marine diesel and fuel oil (for inland, coastal, and ocean-going vessels), and fuels within the distribution chain. Suitable for measuring sulfur content—ranging from 16 ppm to 4.6%—in various petroleum products (takie jak benzyna, diesel, ciężki olej, and residual fuel oil), dodatki, lubricants containing additives, and intermediate products from refining and chemical processes at facilities such as refineries, testing and certification bodies, składy ropy, i laboratoria.

 

It is also suitable for measuring sulfur content in any material across various industries.

 

ASTM D4294 DM1262 Przenośny analizator siarki EDXRF Fluorescencyjny tester siarki rentgenowskiej Maszyna do testowania siarki XRF Miernik siarki Sprzęt do testowania pierwiastków oleju S

Specyfikacja techniczna

Lampa rentgenowska Napięcie: ≤10keV, Aktualny: ≤1mA, Moc: ≤10W
Detektor Ultracienka, proporcjonalna rurka licznika z berylu
Detection Limit (300S) 2.6ppm
Skala 16ppm ~ 4.6%
Linear Error & Analysis Precision Comply with relevant requirements of GB/T 17040, GB 17411, ASTM D4294, itp.
System Analysis Time 1 ~999s; recommended value: 300s or 600s for trace measurement, 100s for constant measurement
Środowisko działania Temperatura: -10℃ ~ 40 ℃, Wilgotność względna: ≤95% (35℃)
Zasilacz Built-in lithium-ion battery pack, 20.8Ah, 22.2V, supports 5 hours working under measuring state
Overall Power Consumption ≤50W
Wymiary & Waga 270mm (W) × 320mm (D) × 174mm (H), 5.2kg (including battery and printer)