plug pins use Gauge

BS1363 Gauge for use with plug pins
The gauge shall be deemed to meet the dimensional requirements (if the measurement results are within the specified dimension and the measurement uncertainty does not exceed 0.005mm when the confidence level does not exceed 95%)
12.2.1 Inspection, measurement and use of gauge as shown in Figure 5. For gauge test, the reconnecting plug should be connected with BS 6500:2000, 1.25mm2 3-core flexible cord as shown in Table 27. Non-reconnecting plugs shall be tested in delivery condition.
Gauge in a roughly vertical position, the plug and gauge fit surface parallel to each other, phase line and the center of the plug into the distance should not exceed 2mm. When a force of 10N or less is applied in a direction perpendicular to the fitting surface, the plug shall enter the gauge completely without any additional force being applied to make it flush. Plug and socket gauge

BS1363 Gauge for use with plug pins
BS1363 Standard for plug and socket gauges
BS1363-Fig1 Test PIN
BS1363-Fig5 Plug and pin gauge
Test device for mounting screws of BS1363-Fig6 joint cover
BS1363-Fig7 Mounting panel
BS1363-Fig8 Plug elastic bending test device
BS1363-Fig10 Pressure test device
BS1363-Fig11max/min socket gauge
BS1363-Fig12 Contact test gauge
BS1363-Fig14 non-contact test gauge
BS1363-Fig15 Socket transverse stress gauge
BS1363-Fig16a/b socket pulling output gauge
BS1363-Fig17a.b Test apparatus and simulation panel for temperature rise test
BS1363-Fig19 Solid stainless steel fuse
BS1363-Fig23 Pressure test device
Test device for BS1363-Fig32 Pin (excluding 1100N device)
BS1363-Fig20 Barrel rolling device
BS1363-Fig24 ball pressure device
Calibration fixture for fuse BS1363-Fig29
BS1363-Fig30 Temperature rise plug
BS1363-Fig33 Torque fixture
Gauge BS1363-Fig34
BS1363-Fig35 gauge
Plug torque test device BS1363-FIG37 meets the requirements of BS1363 standard.