CS-800 Benchtop Spectrophotometer
- Description
- Inquiry
Description
CS-800 Benchtop Spectrophotometer
CS-800 is a highly performance spectrophotometer with top-port test caliber. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula.
It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers’ measurement requirement.
Brief Introduction
1. Solid samples (steel, cloth) can be placed directly on the measurement port, particles (tablets, master batch), powder (pigment, coffee), paste objects (tomato sauce) can be placed in a petri dish, and then placed in the measurement port.
2. D\8 Structure
Our device adopts internationally agreed observe condition D/8 (Diffused illumination, 8 degrees observer) and SCI(specular component included)/SCE(specular component excluded).
3. Can Measure SCI and SCE at the same time
4. ETC Technology (Every Test Calibration)
5.Color QC Software
Our spectrophotometer comes with PC color QC software, which is applicable in various industries for management of color data. It is used for store test result,generate test report and print test report after connect with printer.
6. More Product Pictures
7. Technical Data
Type | CS-800 |
Illumination | d/8(Diffused illumination, 8°viewing) (conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standards) |
Size of integrating sphere | Φ40mm,Alvan diffused reflection surface coating |
Illumination Light source | CLEDs(entire wavelength balanced LED light source) |
Sensor | dual optical path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Resolution | 0.01% |
Observer angle | 2°/10° |
Measurement Light Source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,DLF,TL83,TL84,NBF,U30,CWF |
Data being displayed | Reflectance graph/value, chromatic value, color difference values, color assessment results, color tendency, display measurement area, history color value simulation, manual input standard sample, generate measurement reports |
Measurement time | About 1 second |
Measurement time interval | 0.5 second |
Measuring caliber | Φ11mm |
Color space | CIE-L*a*b,L*C*h,L*u*v,XYZ,Yxy,reflectivity,Hunterlab,Munsell MI,CMYK,RGB,HSB |
Color difference formulas | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555color classification |
Other colorimetric indices | WI(ASTM E313-00,ASTM E313-73,CIE/ISO,AATCC,Hunter,Taube Berger Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Tint(ASTM E313,CIE,Ganz),metamerism index Milm, adhesive/changing color fastness, ISO luminance,8 gloss, A density, T density, E density, M density |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values: ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum: 0.03 | |
Battery capacity | rechargeable, 20000 continuous tests, 7.4V/6000mAh |
Interface | USB |
Data storage | 40000 test results |
Light source longevity | 5 years, 1.5 million tests |
Inter-instrument agreement | ΔE*ab within 0.2 (BCRA color charts II, average of the 12 charts) |
Size | 350*300*200mm(L*W*H) |
Weight | 4.5kg |
Display | 5 inches True color screen |
Work temperature range | 0~45℃, relative humidity 80% or below(at 35°C), no condensation |
Storage temperature range | -25℃ to 55℃, relative humidity 80% or below(at 35°C), no condensation |
Standard accessories | AC power line, operating manual, color QC software, driving software, electric operating manual, USB cable, white/black calibration tile, verification certification |
Optional accessories | powder molding device, cuvette, shading cover |
Color matching system | Matches |
UV light source | without |
8. Application
9.Technical Support
a. One Year Guarantee Time.
b. If testing data is not correct, we can do refund.
c. We will provide testing report for every device to assure the authority of the data and it will save the calibration cost for 1 year.