LR-N3100 Automatic wet laser particle size analyzer

LR-N3100 is our company’s new portable integrated particle size meter, with small volume, large range, high degree of automation and many advantages, the whole machine only 750mm*270mm*315mm (including integrated ultrasonic, dispersion, circulation), although the volume is small range has reached 0.1μ m-500 μmLR-N3100 is a wet automatic laser particle size analyzer, which adopts the most advanced Mie scattering principle and the concentrating Fourier transform light path. High-density probe and full range seamless test method ensure the accuracy and repeatability of test results.

Nkt3100-l operation process is completed automatically by computer control,

 

 LR-N3100 Automatic wet laser particle size analyzer

 control system schematic diagram is as follows:

Control system principle diagram of intelligent laser particle size analyzer

LR-N3100 laser particle size analyzer main performance characteristics:

★ Advanced optical path design:LR-N3100 using concentrating Fourier transform testing technology to ensure the shortest focal length to obtain the maximum range, effectively improve the resolution of the instrument; The unique high density detection unit enables the 3100-L to have super small particle testing ability. The high density detection unit enables the LR-N3100 to have super full range seamless testing ability.

Fully sealed fiber semiconductor laser: LR-N3100 uses the high stability, long life of Japan Mitsubishi fully sealed fiber semiconductor laser, excellent stability so that the particle size instrument has a strong test repeatability, LR-N3100 laser power size adjustable, the maximum laser power has also done 20MW.

Automatic test: truly automatic test, what you do is just put in the sample, no interference data without manual selection of data.

 Ultrasonic anti-dry burning function: LR-N3100 can realize ultrasonic anti-dry burning function, avoid damage to ultrasonic without water.

New SOP self-editing function: in order to meet the test needs of different samples,LR-N3100 realized the SOP self-editing function, according to different samples to edit different test process, after one edit and save, directly use next time.

Dustproof and shockproof design: the whole instrument is sealed to greatly improve the service life of the internal components. The unique shockproof structure can effectively avoid the interference of external vibration to the instrument, so that the test results are more stable and reliable.

Optical path adjustment: computer remote control precision self-locking motor, precision guide rail, precision controller and software system composition, minimum step distance of 1 micron, to ensure that the laser beam focus always through the center point of the detector, improve the accuracy of test results and repeatability. Automatic centering system is the standard configuration of all types of Laser particle size meter.

Free exhaust bubble design: the new design makes the whole test will not have bubble into the test sample window, avoid bubble interference.

Channel steel guide: the light path guide is uniformly upgraded from aluminum alloy to thickened channel steel, the light path system is more stable and reliable, and greatly reduces the influence of temperature and humidity on the light path.

Sample no residue design: the instrument pipeline and drainage structure are optimized design, the instrument pipeline, circulation pump no liquid residue, to avoid the impact on the next test data.

 Sample window quick change device: newly designed sample window quick change device, make sample window more convenient and fast change.

LR-N3100 Automatic wet laser particle size analyzer 

Main technical parameters:

specificationsLR-N3100(The standard)
Execution standardISO 13320-1:1999;GB/T19077.1-2008
Test range0.1μm -500μm
Number of detector channels65
Accuracy error< 1% (National standard sample D50 value)
Repeatability error< 0.5% (National standard sample D50 value)
Free bubbleWith no exhaust bubble design, no bubble interference data more accurate
Misoperation protectionThe instrument has self-protection function for misoperation and does not respond to misoperation
Laser parameterImported fiber output high power laser λ= 635nm, P> 20mW
The light path calibrationAutomatic optical path calibration
Dispersion methodultrasonicFrequency: F =40KHz, power: P =100W, time: adjustable; With ultrasonic anti-dry burning
Circulating and stirringIntegrated design of circulation mixing, speed: adjustable 100-4000rpm
Circular flowRated flow: 0-10L/min Adjustable rated power: 20W
The sample poolSelf-designed boiling sample tank, better dispersion effect, capacity: 190-600ml can be normal test
Dustproof and shockproof designThe whole machine adopts dustproof and shockproof design
Software functionsAnalysis patternsIncluding free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods
Statistical methodsVolume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries
Statistical comparisonIt can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials
To DIYUser-defined data to display, according to the percentage of particle size, according to the percentage of particle size or according to
According to the templateThe percentage of particle size interval is calculated to meet the characterization of particle size test in different industries. Diameter distance, consistency, interval accumulation, etc
The test reportThe test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion
Multilingual supportChinese and English language interface support, can also be embedded in other languages according to user requirements.
Intelligent operation modeTruly automatic unmanned intervention operation, no human interference, you only need to add the sample to be tested as prompted, the test results of better repeatability.
Operating modeOne-click automatic software operation mode
The test speed< 1min/ time (excluding sample dispersion time)
volume750mm*270mm*315mm
The weight of the25Kg

 