Description

LR-N6100 Wet process intelligent automatic laser particle size analyzer

LR-N6100 adopts the most advanced Mie scattering principle and the convertive Fourier transform optical path. High-density probe and full range seamless test method ensure the accuracy and repeatability of test results. The unique wet circulation dispersion system ensures that there is no particle deposition during the particle test and no waste liquid accumulation after the test drainage, which ensures the accuracy of the second test and makes the test results more authentic and reliable. At the same time, no residue design is adopted to ensure the accuracy of testing different samples. Superior light path automatic calibration system highlights the unique advantages of LR-N6100 .

LR-N6100 Advanced optical path design: LR-N6100 using concentrating Fourier transform testing technology to ensure the shortest focal length to obtain the maximum range, effectively improve the resolution of the instrument; Unique high density detection unit, let 6100 has a super small particle testing ability, high density detection unit makes LR-N6100  has a super full range seamless testing ability, high edition adopts double optical path design.

Dustproof and shockproof design: the whole instrument is sealed to greatly improve the service life of the internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument, so that the test results are more stable and reliable.

Optical path X, Y direction automatic calibration: LR-N6100  exclusive use of mechanical center and optical center combined technology, optical path automatic adjustment positioning more accurate, micron level; At the same time, the speed of optical adjustment is faster and the fastest adjustment can be completed in 15 seconds.

 Intelligent automatic operation mode: software to achieve one-button operation, automatic water, automatic sampling, automatic testing, automatic cleaning, the whole test process to achieve one-button automatic operation, easy to use.

Unique micro circulation system: the whole dispersion circulation system has been optimized design, the dispersion medium is more than 180 ml can cycle test, really achieve the micro circulation test; All joints adopt the design of quick insertion and quick twist, all pipes can be replaced in a short time; The optimized design ensures no waste residue after drainage and the accuracy of the next test result.

LR-N6100-c has a range of 0.1 μm ~ 2000μm.

Ultrasonic anti-dry burning: LR-N6100 is equipped with 100W high-power ultrasonic, and has the function of ultrasonic anti-dry burning.

 Misoperation protection: LR-N6100 has self-protection function, some will damage the instrument misoperation does not respond, greatly reduce the damage caused by human misoperation.

 Dew point measurement: sample window fog will affect the accuracy of measurement, such test results have no practical significance, LR-N6100 with a fog point measurement system, once the fog software will automatically prompt.

 Free exhaust bubble design: the new design makes the whole test process will not have bubbles into the test sample window, to avoid the bubble interference (free exhaust bubble function technology we have the exclusive).

 Sample residue free design: the instrument pipeline and drainage structure are optimized design, the instrument pipeline, circulation pump without liquid residue, to avoid the impact on the next test data; The dry test was also designed to be residue free.

 Sample window quick change device: newly designed sample window quick change device, make sample window change more convenient and fast (20 seconds to complete the sample window disassembly process).

LR-N6100 Wet process intelligent automatic laser particle size analyzer

The stability and repeatability reach the foreign malvern instrument standard

Main technical parameters:

specifications

LR-N 6100

Execution standardISO 13320-1:1999;GB/T19077.1-2008
Test range0.1μm -2000μm
Number of detector channels90
Accuracy error< 0.5% (National standard sample D50 value)
Repeatability error< 0.5% (National standard sample D50 value)
Free bubbleWith no exhaust bubble design, no bubble interference data more accurate
Misoperation protectionThe instrument has self-protection function for misoperation and does not respond to misoperation
Laser parameterImported fiber output high power laser λ= 635nm, P&GT; 10mW
The light path calibrationAutomatic optical path calibration
Dispersion methodultrasonicFrequency: F =40KHz, power: P =80W, time: adjustable; With ultrasonic anti-dry burning
Circulating and stirringIntegrated design of circulation mixing, speed: 100-33950 RPM adjustable speed
Circular flowRated flow: 0-30L/min Adjustable rated power: 25W
The sample poolSelf-designed boiling sample tank, better dispersion effect, capacity: 190-600ml can be normal test
Microinjection (optional)The instrument can be equipped with micro automatic test device,10 ml can be cyclic test (optional)
Dustproof and shockproof designThe whole machine adopts dustproof and shockproof design
Anti-corrosion design (optional)Can be equipped with acid resistance, alkali resistance, oil resistance (including all solvent oil), resistance to organic solvents (such as acetone, phenol, n-hexane and other organic solvents).
Software functionsAnalysis patternsIncluding free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods
Statistical methodsVolume distribution and quantity distribution, in order to meet the different statistical methods of granularity distribution in different industries
Statistical comparisonIt can make statistical comparison and analysis for multiple test results, and can obviously compare the difference of test results of different batches of samples, samples before and after processing and different time, which has strong practical significance for the quality control of industrial raw materials
DIY display templateThe user defines the data to be displayed, and calculates the percentage according to the particle size, the percentage according to the particle size or the percentage according to the particle size interval, so as to meet the characterization method of particle size test in different industries. Diameter distance, consistency, interval accumulation, etc
According to the templateThe test report can be exported to Word, Excel, Bmp, and Text files, enabling you to view test reports and reference test results in scientific research articles on any occasion
The test reportChinese and English language interface support, can also be embedded in other languages according to user requirements.
Multilingual supportTruly automatic unmanned intervention operation, no human interference, you only need to add the sample to be tested as prompted, the test results of better repeatability.
Intelligent operation modeIncluding free distribution, R-R distribution and log-normal distribution, classification by order statistical mode, etc., to meet the different requirements of different industries for sample size statistical methods
Operating modeOne-click automatic software operation mode
The test speed< 1min/ time (excluding sample dispersion time)
volume980mm*410mm*450mm
The weight of the35Kg






    has been added to your cart: