Significado e uso
4.1 A capacidade dos materiais plásticos de resistir à degradação causada pela exposição à luz, heat and water is of great importance in many applications. This practice is designed to induce performance changes related to end-use conditions, including the effects of ultraviolet solar irradiance, humidity and heat. The exposures used in this practice are not intended to simulate deterioration caused by local weather phenomena, such as atmospheric pollution, ataques biológicos, e exposição à água salgada. CaveatWithin the accepted limits of this practice, changes in operating conditions do not necessarily provide the same results. Portanto, reference to the use of this practice should not be made unless accompanied by a report describing the specific operating conditions used in accordance with section 8. Please refer to Practice G151 for more information on the precautions applicable to the use of results obtained under this practice.

Observação 2: Para obter informações adicionais sobre fontes de variabilidade e estratégias para lidar com a variabilidade no projeto, execução, and data analysis of laboratory accelerated exposure tests, consulte o Guia G141.

4.2 The reproducibility of test results between laboratories has been shown to be good when evaluating the stability of a material according to its performance class compared to other materials or controls. 5,6 Portanto, it is strongly recommended to expose similar materials with known properties (controles) ao mesmo tempo que o material de teste. At least three repetitions of each material are recommended to enable statistical evaluation of the results.

4.3 Test results will depend on the degree of care taken to operate the equipment in accordance with practice G154. Important factors include the regulation of the line voltage, the temperature of the equipment working room, controle de temperatura, and the condition and age of the lights.

Prática padrão ASTM D4329-2021 para exposição de ultravioleta fluorescente (ultravioleta) Instalações de lâmpadas para plásticos

Raio
1.1 This procedure covers specific procedures and test conditions applicable to exposure to plastics using fluorescent UV lamps and water equipment in accordance with practices G151 and G154. The practice also includes the preparation of the sample, the test conditions suitable for the plastic, and the evaluation of the test results.

1.2 Os valores expressos em unidades SI serão considerados valores padrão. Os valores dados entre parênteses são apenas para referência.

1.3 Esta norma não se destina a abordar todas as questões de segurança, caso existam, associado ao seu uso. É responsabilidade dos usuários desta norma estabelecer medidas de segurança apropriadas, práticas de saúde e ambientais e para determinar a aplicabilidade de restrições regulatórias antes do uso.

Observação 1: This standard and ISO 4892-3 cover the same topic, but differ in their technical touch.

1.4 Esta norma internacional é baseada em princípios de padronização reconhecidos internacionalmente, estabelecidos na Decisão sobre Princípios para o Desenvolvimento de Normas Internacionais, Diretrizes e recomendações emitidas pelo Comitê da OMC sobre Barreiras Técnicas ao Comércio.