- Descrição
- Investigação
Descrição
According to :IEC60065, CEI 60335-1, CEI 60529, IEC60884-1, IEC60950, CEI61032, IEC69
Aplicativo:
1, The joint part of The Standard Test Knurled Finger Probe can’t touch the live parts or close to the dangerous parts, e 50 mm to 20 mm baffle plate cannot enter.
2, In the prevent electric shock test, wires , power devices, and lighting devices are needed.
3,Both joints shall permit movement in the same plane and the same direction through an angle of 90° with a 0° to +10° tolerance
OBSERVAÇÃO 1:Using the pin and groove solution is only one of the possible approaches in order to limit the bending angle to 90°. For this reason, dimensions and tolerances of these details are not given in the drawing. The actual design must insure a 90° bending angle with a 0° to + 10° tolerance.
OBSERVAÇÃO 2: Dimensions in parentheses are for information only.
OBSERVAÇÃO 3: The test finger is taken from IEC 60950-1, Figure 2A. That test finger is based on IEC 6103216), Figure 2,test probe B. Em alguns casos, the tolerances are different.
Knurled Finger Diameter | 12milímetros |
Knurled Finger Length | 80milímetros |
Baffle Plate Diameter | 50milímetros |
Baffle Plate Length | 100milímetros |