Sistema de teste on-line e de envelhecimento do motor, analisador de velocidade de torque, desempenho do motor e testador de aumento de temperatura
- Descrição
- Investigação
Descrição
Visão geral do sistema
This test system is a dedicated testing equipment for motor performance and temperature rise.
Inclui principalmente:
- No-load performance test
- Load performance test
- Fixed-point test
- Locked-rotor test
- Online test
- Aging test
The system adopts high-precision power analyzers and torque-speed measuring instruments, which can accurately measure the voltage, atual, potência de entrada, velocidade, torque, potência de saída, and efficiency of various types and grades of motors.
This system is a dedicated testing equipment for motor performance. It features high testing accuracy, boa repetibilidade, forte estabilidade operacional, alta eficiência paralela, longa vida útil, e facilidade de uso. It has both manual and automatic control modes. The manual control mode operates independently of the computer system, while the automatic control mode is controlled by the computer. The automatic test system provides full Chinese software, que pode exibir e imprimir curvas características de saída e dados:
n = f(você, EU, P1, COSφ, M, P2, ou)
M=f(você, EU, P1, n, COSφ, P2, ou)
Ele pode testar e exibir os seguintes dados: tensão de entrada, atual, potência de entrada, torque, velocidade, potência de saída, e eficiência do motor testado. Ele pode exibir e imprimir dados de teste e carregar curvas características, com vários formatos de saída disponíveis.
Itens de teste
2.1 Tensão de entrada do motor, atual, e poder
2.2 Torque de saída do motor, velocidade, e potência de saída
2.3 Eficiência geral
Measuring Instruments
4.1. Motor Performance Analyzer (Speed and Torque Measurement Instrument)
1) Measurement Range and Accuracy:
2) Ambiente operacional:
Temperatura: (0~40)℃;
Umidade: (20%~75%) RH;
Atmospheric Pressure: (86~106) kPa;
Instrument Power Supply: AC220V±22V, 50Hz±1Hz;
3) Comparison
The torque and speed analyzer provides a variety of test modes, including three basic modes (excitation current, velocidade constante, and constant torque) and three special modes (automatic slope, endurance test, and stall point test). The three basic modes can be quickly switched using the “PID Mode” button on the instrument’s front panel. Special modes require a PC or standalone device to complete the testing functions, breaking away from traditional measurement methods.
4) PID Calculation Method
The controller uses a PID (proporcional, integrante, and derivative) control law. When the controller and the controlled object form a closed-loop control circuit, to ensure that the system operates with optimal dynamic and static performance, the proportional coefficient and integral and derivative time constants of the control loop need to be tuned according to the specific conditions of the controlled object. The system’s dynamic performance is mainly determined by the proportional coefficient. The purpose of tuning the proportional coefficient is to ensure stable operation while achieving the fastest response speed and the smallest steady-state error (the difference between the set value and the actual output value). The integral term eliminates the system’s steady-state error. If the integral action is too strong, it will cause oscillations in the system; if the integral action is too weak, it will take too long to eliminate the steady-state error. Tuning the integral time constant aims to ensure that the control loop eliminates the steady-state error as quickly as possible while maintaining stable operation. The derivative term suppresses oscillations and reduces hysteresis. If the derivative action is too weak, the effect is not obvious; if the derivative action is too strong, it will amplify system noise, making the system operation erratic.
The dynamometer controller divides the PID coefficients (representing the strength of proportional, integrante, and derivative actions) into 0-99 levels according to their strength. These codes (0-99) are called PID parameters. Each different control mode requires its own independent set of PID parameters. The tuning of the P parameter involves finding the P value close to the critical oscillation point to minimize the steady-state error and achieve the fastest response. When tuning PID parameters, the order should be P, EU, e D. Primeiro, tune the proportional parameter. When searching for the optimal proportional parameter, the effects of integral and derivative actions should be minimized to avoid their influence. If the approximate range of the proportional parameter is unknown beforehand, it is easy to adjust the proportional parameter from small to large. For each value tested, the setpoint of the controlled variable should be changed significantly. If no oscillation occurs, the value can be increased further until the point where oscillation begins is found. Então, decrease the proportional parameter by one step to obtain the optimal proportional parameter.
The tuning of the I parameter involves finding the I value close to the critical oscillation point to minimize the time to reach the setpoint.
After tuning the P parameter, tune the I parameter under the optimal P parameter. De forma similar, the integral parameter should be adjusted from small to large. For each value tested, the setpoint of the controlled variable should be changed significantly. If no oscillation occurs, the value can be increased further until the point where oscillation begins is found. Então, decrease the integral parameter by one step to obtain the optimal integral parameter.
The tuning of the D parameter involves finding a suitable D value that can significantly suppress overshoot without causing significant noise. Finalmente, tune the D parameter. Under the optimal P and I parameters, adjust the derivative parameter from small to large. No entanto, the D parameter does not have a clear oscillation boundary like the P and I parameters. As the D value increases, periodic oscillation will not occur, but rather increasingly noticeable random noise. Portanto, when adjusting the D parameter, it is not necessary to seek the optimal critical value as with the P and I parameters; simply find a value that significantly suppresses overshoot without causing significant noise.
4.2 Electrical Parameter Tester
Main performance and technical specifications:
| Parâmetros | Faixa de medição: | Working error: | Resolução: | Observações: |
| Tensão | (1–300) V | ± (0.4% of reading + 0.1% de escala completa)
Working error: |
<100 V: 0.01 V
≥100 V: 0.1 V |
Overload up to 1.2 times the range is permitted. |
| Atual | (0.005–20) A | 0.001 A | Overload up to 1.2 times the range is permitted. |
Input method: Both voltage and current are floating inputs;
Maximum peak value of measurement signal: Both voltage and current are 1.6 times the maximum range;
Conversion rate: Aproximadamente 4000 times/second;
Display update: Aproximadamente 5 times/second;
Overall power consumption: < 5C;
Peso do instrumento: Aproximadamente 3 kg;
Dimensões do instrumento: Width x Height x Depth: (310 x 121 x 328) milímetros. Opening dimensions: Width x Height (307 x 102) milímetros
Ambiente operacional:
Pressão atmosférica: (86–106) kPa;
Temperatura: (0–40) ℃;
Humidade relativa: ≤85% UR
Instrument power supply: AC 220V±15% 50/60Hz
Requerimentos gerais:
Resistência de isolamento: The insulation resistance between the following terminals shall be no less than 2MΩ;
Withstand voltage: The following terminals shall withstand a 2000V 50Hz sine wave voltage;
Between the measuring terminals and the casing; between the power cord and the casing; between the measuring terminals and the power cord.
Observação: For definitions of the terms used in the above technical parameter descriptions, please refer to GB/T 13978-1992 “General Technical Specifications for Digital Multimeters”.
Software Function Introduction
- Itens de teste:
(1) During no-load, carregar, and locked-rotor tests, safety values for current, torque, velocidade, and output power can be set, enabling automatic limit triggering.
(2) Automatic and Manual Load Testing:
Load test loading speed is adjustable: adjustable according to actual needs.
Test load increment is adjustable: the initial load and increment can be set.
(3) Fixed-Point Testing: Atual, torque, velocidade, and power can be tested. Testing can be performed at a single point without unloading; or at multiple points with unloading.
(4) Endurance Testing: Operating modes: sem carga, torque, potência de entrada, potência de saída, and other parameters can be freely set; the endurance value and error value under each item can be freely set; the test time can also be freely set.
- Nameplate Parameters:
Motor model, potência nominal, tensão nominal, velocidade nominal, customer name, customer file, test personnel, test date.
- Curve Coordinates:
(1) Two modes, seven coordinate curves.
(2) Two modes: speed mode and torque mode. These two modes only represent different ways of analyzing the data.
(3) Seven curves: tensão, atual, velocidade, torque, potência de entrada, potência de saída, e eficiência. The maximum value and color of each curve can be freely set for convenient data analysis.
- Storage and Retrieval of Motor Parameters:
After setting the parameters for each motor, they can be stored for future use and retrieval without needing to reset them.
- Motor Performance Test Interface:
The testing interface can display real-time test data (tensão, atual, velocidade, torque, potência de entrada, potência de saída, e eficiência) and collect data at set intervals (which can be freely configured). Curves are automatically plotted during the testing process, allowing for better monitoring of the test.
- Report Analysis:
(1) Curve graphs of the entire testing process (tensão, atual, velocidade, torque, potência de entrada, potência de saída, e eficiência)
(2) Nameplate parameter values
(3) Key motor performance analysis points:
No-load point: Current value and speed value
Maximum torque point: Torque value, speed value, valor atual, output power value, and efficiency value
Maximum output power point: Torque value, speed value, valor atual, output power value, and efficiency value
Highest efficiency point: Torque value, speed value, valor atual, output power value, and efficiency value
Main Configuration List
| General term | Nome | unidade | quantidade | Observação |
| Dynamometer loading system | High-precision magnetic powder dynamometer | definir | 2 | Velocidade de rotação: 3000 rpm
Rated torque: 10 Nm Built-in torque and speed sensor Método de resfriamento: Resfriamento a água |
| Dynamometer test bench | definir | 2 | Configuração padrão | |
| Refrigerador | definir | 2 | Configuração padrão | |
| Motor-specific mounting fixture | definir | 2 | Customized according to customer product specifications, including coupling | |
| Calibration tooling | definir | 1 | Free gift | |
| Measurement and control section | Torque and speed measurement and control instrument | unidade | 2 | Controle PID, communication method, remote/local selectable, disturbance-free switching of control modes, includes torque signal acquisition module. Can automatically load, maintain constant speed, and maintain constant torque. Includes excitation loading. |
| Electrical parameter tester | unidade | 2 | Tensão: 300V Current: 20A | |
| Operator console | definir | 1 | Vertical control panel including key switch, emergency stop button, start/stop buttons, fusível, contactor, etc.. | |
| Computador industrial | definir | 1 | Yanxiang IPC310, 17-inch Lenovo monitor, 6 serial ports, porta de rede, Interface USB | |
| CLP | definir | 1 | Mitsubishi | |
| Testing software | definir | 1 | Motor testing dedicated software |