Descriere

Rubber Rheometer ASTM D5289 ISO 6502

Summary of the equipment

LR-A018 type no rotor rheometer is used to control the quality of rubber, rubber processing industry rapidly test and rubber basic research, the most widely used instrument for rubber optimization combination formula provides accurate data, can be precisely measured scorch time, positive rheometer time, sulfide, index and parameters such as maximum and minimum torque.

 

Rubber Rheometer ASTM D5289 ISO 6502

Caracteristici principale

1、The non-rotor rheometer adopts the latest version of the latest domestic software, which has the characteristics of fast heating (within 3 minute) and high temperature control.

2、The nonrotor rheometer adopts alphasealed cavity structure and is in the international leading position.

3、The nonrotor vulcanizer adopts advanced alpha force sensor technology.(Sensor accuracy 0.001N.m)

4、No rotor rheometer using advanced alpha type sealed cavity structure, by importing seal rotating cavity and fixed sealed cavity, and closed type cavity and the general structure of the open cavity is not the same, its precision and requirements and advanced nature is not matching.Airtight mold cavity repeatability completely consistent, in the international leading position.

Working principle:

Put rubber sample in almost completely sealed cavity, and maintain under the test temperature, the cavity has a fluctuation two parts, one part under with tiny linear reciprocating movement (swing oscillation), oscillation samples can produce shear strain, the determination of sample of cavity reaction torque (power), the torque (power) depends on the size of the shear modulus of the rubber.

Sulfide increases the shear modulus of samples after the trial begins, computer machine real-time display and record torque (power), when the torque (power) up to a maximum stable value or even return status, then get a torque (power) and the relation curve of time, și anume, vulcanization curve (as shown in figure 1), the shape of the curve and test the temperature and the properties of the rubber.

Application industry

It is the most important testing instrument for the development of new products, the research of the formulation of rubber materials, the control of the quality of rubber materials and the application of rubber basic research.It is widely used in all kinds of rubber products.

Standard de testare

The non-rotor vulcanization test instrument conforms to GB/T16584 rubberdetermination of vulcanization characteristics by non-rotor vulcanization instrument, ISO6502 requirements and the Italian standard requirements of T10, T30, T50, T60, T90 data.

Rubber Rheometer ASTM D5289 ISO 6502

Specificație tehnică

ModelLR-A018
Temperature range controlRT—200℃
Temperature fluctuation range±0.15℃
Torque resolution1/500000
Torque accuracy0.3%
Torque unitN.mN.cmN.inchkN.mkN.cmkN.inchkg.mkg.cmkg.inchlp.mlp.cmlp.inchg.mg.cmg.inch
Rezoluția afișajului temperaturii0.01℃
Temperature recovery time after mold closing< 1.5min
Temperature unitC(degree centigrade )F(Fahrenheit)K(Kelvin)
Sampling rate200times/S
Support languageEngleză, simplified Chinese, traditional Chinese
Standard de testareGB/T 16584、ASTM D5289、ISO 6502
calculating parameterts1ts2t10t30t50t70t90Vc1Vc2
Software connectorUSB2.0
Print dateDate, timp, temperatura, cure curve, temperature curve

MLMHts1ts2t10t50t90Vc1Vc2

test standardASTM D 5289, ISO6502
oscillation frequency100 cycles per minute(1.67Hz)
amplitude of oscillationconfigurație standard: ±1degree ±0.03degree
【optional】±0.5degree±0.03degree, ±3degree±0.03degree
Variable temperature time170℃→190℃ within 55s ±0.3℃

190℃→170℃ with 1minute 40s ±0.3℃

 

Temperature return time after membrane closure

temperature compensation is restored to the set temperature of 170℃(error±0.3℃)not big than 30±3s
Viteza de incalzireRT→170℃ 2minutes 40s ±0.3℃
Putere

Sursa de aer

220VAC±10%, 50±3Hz

Min minimum 65psi (4.5kg/cm2)

mărimeaL65cm x W59cmx H148cm
GreutateGross: 300kg , Net: 250kg