Опис

E40 7006-53-1 Anti-accidental electric shock gauge

E40 lamp holder and holder gauge technical standard: ГБ 1483.1-2008; ИЕЦ 60061-3:2004

Gauge for inspecting finished lamps with E40 caps against accidental contact


The plunger of the gauge is shown in the test position. When the plunger is at rest, surface W shall be retracted deeper than surface V.

ReferenceДимензија(мм)Толеранција(мм)ReferenceДимензијаТолеранција
Д39.6+0.0/-0.02П21±0.1
Ф40.2+0.05/-0.0П32±0.1
G44+0.05/-0.0РApprox.25
Х22±0.1У12±0.1
M50.4±0.1р4.5+0.5/-0.0
Н51.4+0.0/-0.02α35°±30

E40 7006-53-1 Anti-accidental electric shock gauge

сврха:

To check protection against accidental contact during insertion of caps E27 on finished lamps.

E40 7006-53-1 Anti-accidental electric shock gauge
Testing :

The shape of the lamp with regard to protection against accidental contact is assumed to be correct if, when the lamp is pushed as far as possible into the gauge, surface W does not protrude beyond surface V.

E40 7006-53-1 Anti-accidental electric shock gauge
сврха:

To check protection against accidental contact during insertion of caps E27 on finished lamps.

E40 7006-53-1 Anti-accidental electric shock gauge
Testing :

The shape of the lamp with regard to protection against accidental contact is assumed to be correct if, when the lamp is pushed as far as possible into the gauge, surface W does not protrude beyond surface V.






    је додато у вашу корпу:
    Провери