ASTM D 1310-01-2007 “จุดวาบไฟและจุดติดไฟของของเหลว ทดสอบโดยเครื่องเปิดถ้วย Teger”

ความหมายและวัตถุประสงค์
The test method in this standard can be used to measure U in 99Tc, 230ไทย, และ 234 soil samples. The test method is applicable to soils contaminated by nuclear-related activities such as uranium ore processing and uranium enrichment. The FI concentration step can reduce the detection limit by about 10 times compared to ICP-MS introduced for conventional samples. The approximate IDL is listed in Table 1.

ขอบเขตของ
1.1 This test method includes measurement procedure 99Tc and measurement procedure 230 days and 234U in the soil. Applicable to background soils and soils contaminated by nuclear processes. It is intended as an alternative to radiochemical methods as it is faster, requires less labor, and produces less waste than many radiochemical methods.

1.2 The samples were dried, พื้น, melted and dissolved, and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Sequential flow injection (FI) technology is used to provide a lower detection limit than that obtained by direct inhalation ICP-MS and, at 99Tc, to provide isolation from interference.

ที่ 1.3230 day and 234U procedures also work for 232Th, 235ยู, and 238U, but FI preenrichment is generally not required to measure these isotopes at the concentrations typically found in soil.

ASTM D 1310-01-2007 “จุดวาบไฟและจุดติดไฟของของเหลว ทดสอบโดยเครื่องเปิดถ้วย Teger”

1.4 This test method is guided by SW-846 and the quality control procedures derived from the U.S. EPA Inorganic Analysis Program as reported in the Contract Laboratory Program Work Instructions. The level of quality control required may vary from laboratory to laboratory and project to project. Laboratory statistical quality control procedures are required to ensure the reliability of this test method.

1.5 becquerels (Bq) is an acceptable metric unit of radionuclide activity. อย่างไรก็ตาม, picocuries (pCi) are generally the units used to represent regulatory limits for radioactivity. Values expressed in any of these units should be considered standard values. ค่าที่ระบุในแต่ละระบบอาจไม่เท่ากันทุกประการ; ดังนั้น, each system needs to be used independently of the other, rather than combining values in any way.

1.6 Refer to Practice C 998 for information on soil sample collection.

1.7 มาตรฐานนี้ไม่ได้มีวัตถุประสงค์เพื่อแก้ไขปัญหาด้านความปลอดภัยทั้งหมด, ถ้ามี, ที่เกี่ยวข้องกับการใช้งาน. เป็นความรับผิดชอบของผู้ใช้มาตรฐานนี้ในการกำหนดแนวทางปฏิบัติด้านความปลอดภัยและสุขภาพที่เหมาะสม และเพื่อพิจารณาการบังคับใช้ข้อจำกัดด้านกฎระเบียบก่อนใช้งาน.

แชร์โพสต์นี้