คำอธิบาย

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector
การใช้งาน

อาหาร, อิเล็กทรอนิกส์, ยานยนต์, ไฟฟ้า, ครอบคลุม

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector
PYGCMS pyrobenzene detector product features:

1, advanced ceramic heating mode, ceramic body equipped with high precision temperature sensor, precise temperature control, solution straw heating fast and stable, low voltage work, ปลอดภัยและเชื่อถือได้.

2, with the program temperature function, you can set different temperature intervals and gradients;

3, PC software control system, larger expansion performance, การดำเนินงานที่สะดวกยิ่งขึ้น;

4, abandon the traditional mechanical valve, the use of CNC solenoid valve, gas path control more accurate;

5. Cooperate with EPC electronic pressure controller to better control gas flow rate;

6, equipped with electronic type gas pressure regulator valve and needle type pressure valve, to achieve full computer precise control; Independent intellectual property rights of the valve switching system, no dead volume, stable and efficient, no sample residue.

7, according to the needs of users, different diameters of the sample in the straw heating treatment, the highest temperature can be controlled at 500ºC. The desorption device is installed directly on the sample inlet of the gas chromatograph to ensure rapid desorption of the sample into the chromatography.

8, can directly to the standard atmospheric sampling tube or any solid material containing organic matter desorption, desorption, sampling analysis.

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector
Parameter description of PYGCMS pyrobenzene detector:

cracking device (Φ6 cracking pipe) ช่วงอุณหภูมิroom temperature ~ 450ºC, with an increment of 1ºC set.
cracking device (Φ6 cracking tube) อัตราความร้อน>500ºC/ min.
cracking device cracking time range0.01 ~ 99.99min, with an increment of 0.01min set
The purging time range of the cracking device0.01 ~ 99.99min, with an increment of 0.01min
Purge flow range of the cracker10ml ~ 200ml.
the separation flow range of the cracking device10ml ~ 200ml.
cracking device heating control voltage16VDC
aging cleaning device temperature rangeroom temperature ~ 450ºC, with an increment of 1ºC set (ไม่จำเป็น)
Time range of aging cleaning device1 ~ 1200min, with an increment of 1min

PYGCMS Double injector RoHS2.0 testing instrument Double column pyrobenzene detector

ต้นทุนการจัดซื้อจัดจ้างภายใน 350,000เก็บตัวอย่างทุกวัน30-40 ของพวกเขา
วิธีการฉีดของแข็งหรือของเหลวโดยตรงต้นทุนการใช้งาน/ปี8000 หยวน/ปี
ไม่ว่าจะต้องมีการปรับสภาพทางเคมีหรือไม่ไม่จำเป็นต้องมีการปรับสภาพทางเคมีขีดจำกัดการตรวจจับที่ต่ำกว่า50ppm
เวลาตัวอย่าง20 นาที/ตัวอย่างระดับความยากในการดำเนินงานง่ายและใช้งานง่าย, พนักงานสายการผลิตทั่วไปสามารถทำงานได้
ตัวอย่างการปรับสภาพหรือไม่ไม่จำเป็นจำเป็นต้องมีห้องปฏิบัติการมืออาชีพหรือไม่เลขที่, สภาพแวดล้อมในสำนักงานปกติก็ดี

ไม่จำเป็น

จำเป็นต้องมีการประเมินสิ่งแวดล้อมหรือไม่
ไม่จำเป็น

ไม่ว่าจะมีการผลิตน้ำเสียและก๊าซเสียหรือไม่ไม่มี

เครื่องมือ RoHS2.0






    ถูกเพิ่มลงในรถเข็นของคุณแล้ว:
    เช็คเอาท์