ASTM G152-2021 Metalik Olmayan Malzemelerin Maruz Kalması İçin Açık Alevli Karbon Ark Aletlerinin Çalıştırılmasına İlişkin Standart Uygulama

Anlamı ve kullanımı
5.1 The use of the equipment is intended to cause changes in performance related to the conditions of end use, including the effects of sunlight, nem ve ısı. These exposures may include methods of introducing moisture to the specimen. Maruz kalmanın amacı, atmosferik kirlilik gibi yerel hava olaylarından kaynaklanan bozulmayı simüle etmek değildir., biyolojik saldırılar, ve tuzlu suya maruz kalma. Alternatif olarak, maruz kalma, bir pencere bölmesinden geçen güneş ışığının etkilerini simüle edebilir. Sıklıkla, these exposures will include moisture in the form of humidity.

Not 2: Please refer to Practice G151 for the complete warning guidelines applicable to all laboratory aging equipment.

5.2 Changes in results may be expected when operating conditions vary within the acceptable limits of this practice. Sonuç olarak, bölümün spesifik çalışma koşullarını detaylandıran bir rapor eşlik etmedikçe, bu yaklaşımın kullanımının sonuçlarına hiçbir atıf yapılamaz. 10.

5.2.1 Benzer malzemelerin kullanılması tavsiye edilir. (kontroller) Karşılaştırma amacıyla bir standart sağlamak için bilinen özelliklere sahip numune ile aynı anda maruz bırakılmalıdır.. It is better to use control materials that are known to have relatively poor durability and good performance. Sonuçların istatistiksel olarak değerlendirilmesine izin vermek için, her testte değerlendirilen her materyalin en az üç kopyasının yapılması önerilir.

ASTM G152-2021 Metalik Olmayan Malzemelerin Maruz Kalması İçin Açık Alevli Karbon Ark Aletlerinin Çalıştırılmasına İlişkin Standart Uygulama

adius
1.1 This practice covers the fundamentals and operating procedures for the use of open flame carbon arcs and water installations and aims to reproduce the weathering effects that occur when materials are exposed to sunlight (directly or through window panes) ve nem (such as rain or dew) in actual use. This practice is limited to procedures for obtaining, measuring, and controlling exposure conditions. Some exposure procedures are listed in the appendix; Fakat, this practice does not specify the appropriate exposure conditions for the material under test.

Not 1: Practice G151 describes performance standards for all exposure equipment using laboratory light sources. This practice replaces Practice G23, which describes the very specific design of equipment for carbon arc exposure. The equipment described in Practice G23 is covered by this practice.

1.2 Under controlled environmental conditions, the sample is exposed to filtered open flame carbon arc light. Different filters are described.

ASTM G152-2021 Metalik Olmayan Malzemelerin Maruz Kalması İçin Açık Alevli Karbon Ark Aletlerinin Çalıştırılmasına İlişkin Standart Uygulama

1.3 Sample preparation and result evaluation are included in the material specific method or specification. General guidance is given in Practice G151 and ISO 4892-1. More specific information is described in Practice D5870 about methods for determining post-exposure characteristic changes and reporting these results.

1.4 SI birimlerinde ifade edilen değerler standart kabul edilecektir..

1.5 Bu standardın tüm güvenlik konularını ele alması amaçlanmamıştır., varsa, kullanımıyla ilgili. Uygun güvenliğin sağlanması bu standardın kullanıcılarının sorumluluğundadır., sağlık ve çevre uygulamaları ve kullanımdan önce düzenleyici kısıtlamaların uygulanabilirliğini belirlemek.

1.5.1 If any ozone is generated by the operation of the light source, it should be removed from the sample and the operator through the exhaust system.

1.6 This practice is technically similar to ISO 4892-4.

1.7 Bu uluslararası standart, Uluslararası Standartların Geliştirilmesine İlişkin İlkeler Kararında belirlenen uluslararası kabul görmüş standardizasyon ilkelerine dayanmaktadır., Dünya Ticaret Örgütü Ticaretin Önündeki Teknik Engeller Komitesi tarafından yayımlanan Kılavuz ve Tavsiyeler.

Bu gönderiyi paylaş