Function Introduction

The purpose of this apparatus is to determine the thermal shock resistance of a sample of a specific shape and size under specified test temperatures and cooling media conditions. The sample is subjected to rapid heating and cooling temperature changes, and its damage level is then used to assess its thermal shock resistance. According to user requirements, the apparatus can facilitate the repeated transfer of a sample of a certain volume between high temperature and low temperature environments, or between high temperature and water environments, to determine the material’s thermal shock resistance based on the degree of damage after rapid heating and cooling. The equipment consists of two units: a high-temperature/medium-temperature testing unit and a high-temperature/water testing unit. The high-temperature/medium-temperature testing unit uses silicon carbide tubes for heating in both the high-temperature and low-temperature furnaces, reaching temperatures up to 1400°C. The two furnaces are horizontally positioned (vertical positioning is also available upon user request), with the high-temperature furnace on the left and the low-temperature furnace on the right. In the high-temperature/water testing unit, the high-temperature furnace is on the left and the constant-temperature water bath is on the right. The sample is heated in the high-temperature furnace and then horizontally (or vertically, as per user request) moved into the constant-temperature water bath. Both testing units can perform multiple rapid heating and cooling cycles between the high-temperature furnace and the low-temperature furnace or the constant-temperature circulating water bath, thus completing the thermal shock performance test of the sample. Test boyunca, the transfer of the sample from the high-temperature zone to the low-temperature zone is completed quickly. To prevent significant temperature drops during the transfer, appropriate control measures are in place to ensure that the temperature does not fluctuate significantly and affect the test results.

 

Uygulama Kapsamı

Testing of material properties under high-temperature conditions, as well as reaction rates, reaction kinetics, and activation energy between different reactive substances under high-temperature conditions; Uygulama alanları: havacılık, metalurji, ve diğer endüstriler.

 

Cihaz Özellikleri

In this apparatus, both the high-temperature and low-temperature furnaces use silicon carbide tubes for heating. The two furnaces can achieve continuous temperature adjustment from room temperature to 1400°C and maintain a constant temperature at any point.

 

Teknik özellik

High-temperature furnace (high-temperature zone for thermal shock testing)
Heating element material Silicon carbide tube element
Maximum operating temperature 1400°C
Sıcaklık kontrol doğruluğu Better than ±0.5℃
Sabit sıcaklık bölgesinin uzunluğu 90mm
Inner diameter of furnace chamber 50mm
Maximum allowable thermocouple error ±0.25%t
Distance between thermocouple measuring end and sample Less than 8mm
Maximum heating rate 40°C/dak
Temperature uniformity in the constant temperature zone ≤±2℃
Surface temperature rise of the furnace wall ≤45℃
Vacuum unit Vacuum degree ≤10Pa, pumping speed 4L/s, vacuum gauge accuracy: relative indication error 3%
Gas supply unit This unit is a 3-channel gas mass flow controller, realizing 3 gas paths with continuously adjustable gas flow rate. The gas flow rate range is (0~100) ml/dak. The 3-channel mass flow controller is suitable for inert protective atmospheres such as N2, Ar, and He. It is also equipped with solenoid valves for automatic switching between the three gas paths.