27Jul
27Jul
The application case of bag lifting fatigue testing machine in garbage vest bag
The application case of bag lifting fatigue testing machine in garbage vest bag The bag carrying fatigue testing machine can be used to test the strength and durability of various plastic bags, including garbage vest bags. Garbage vest bag is a common plastic bag used for garbage collection and disposal. Its strength and durability have an important impact on the process of garbage collection and treatment, so the bag lifting fatigue testing machine can be used to evaluate the strength and...
26Jul
ASTM D 3278-2021 Determination of Liquid Flash Point with a Small Closed Cup Apparatus
Meaning and Purpose 5.1 Flash point measurement Sample response to heat and ignition source under controlled laboratory conditions. It is only one of many characteristics to be considered when assessing the overall flammability hazard of a material. 5.2 Flash points are used by government regulators in transportation and safety regulations to define and classify flammable and combustible materials. For a precise definition of these classes, see the specific regulations involved. 5.3 Flash points can indicate the possible presence of highly volatile and flammable...
26Jul
ASTM D 3806-98-2019 “Small-scale Evaluation of Flame Retardant Coatings (2-Foot Tunnel Method)”
Meaning and Purpose 3.1 A number of laboratory procedures are used to evaluate the effectiveness of flame retardant and refractory treatments and coatings. In general, these methods measure three stages of fire development: (1) ignition; (2) Flame spread (the growth rate of the fire); (3) Fire extent. While all three are extremely important, flame spread has been recognized as a major factor relevant for testing flame retardant coatings. 3.2 Flame spread rating based on test method E84 has gained general acceptance from...
26Jul
ASTM D 4206-96-2018 Test for Continuous Combustion of Liquid Mixtures with a Miniature Cup Opener
Meaning and Purpose 4.1 Mixtures of flammable and non-flammable liquids, such as mixtures of alcohol and water, are classified by the US government according to the definition of flammable liquids based on the closed cup flash point method. Therefore, mixtures can be classified as flammable even if they cannot withstand combustion. This test method determines the ability of a liquid mixture to sustain combustion and, when used in conjunction with the closed cup flash point method, indicates the flammability characteristics of...
26Jul
ASTM D 4946-89-2017 Adhesion Resistance of Architectural Coatings
Meaning and Purpose 5.1 Dry paint is often in contact with itself, especially in the area of doors and Windows, and can sometimes stick to itself (block) depending on its hardness, pressure, temperature, humidity and length of time the surface has been in contact. This rigorous test method can be used to subjectively compare and evaluate the adhesion resistance of paints. ASTM D 4946-89-2017 Adhesion Resistance of Architectural Coatings Scope of 1.1 This test method covers an accelerated procedure for assessing the face-to-face adhesion...
26Jul
How to test the pollution resistance of architectural coating?
Testing the pollution resistance of architectural coatings is to ensure that the coatings are able to maintain their properties and appearance when they are eroded by various pollutant substances without problems such as fading, peeling, discoloration or damage due to the erosion of pollutants. Architectural coatings are exposed to the erosion of various pollutants such as rain, dust, dirt, automobile exhaust, etc., which may cause damage to the coating surface. By testing the pollution resistance of the coating, it is...
26Jul