ASTM G154-2016 Standard Practice for the Operation of Fluorescent Ultraviolet (UV) Lamp Equipment for Exposure of Non-Metallic Materials

Meaning and use 5.1 The use of the equipment is intended to cause changes in performance consistent with the conditions of final use, including the effects of the ultraviolet portion of sunlight, moisture and heat. Typically, these exposures will include moisture in the form of condensing humidity. Exposure is not intended to simulate deterioration caused by local weather phenomena such as atmospheric pollution, biological attacks, and salt water exposure. Alternatively, exposure can simulate the effects of sunlight passing through a window...

ASTM G155-2021 Practice for Xenon Arc Lamp Equipment for Exposure of Non-Metallic Materials

Meaning and use 5.1 The device exposes the specimen to light, heat and optional moisture, typically attempting to replicate the changes in specimen characteristics observed in both outdoor and indoor end-use environments. Exposure is not intended to simulate deterioration caused by local weather phenomena such as atmospheric pollution, biological attacks, and salt water exposure. 5.2 This practice allows for a wide range of exposure conditions that may produce significantly different results. Therefore, the results of its use should not be referred to...

Coating defects and treatment methods

Coating defects and treatment methods Spray coating technology often has various defects in the coating process, the causes of these defects and the corresponding treatment methods are as follows: Bubble: Cause The paint viscosity is too high. The filter of the coating machine failed. Paint conveying pressure is too high. The paint circulates in the device for too long, resulting in increased viscosity and bubbles. The distance between the knife edge of the spray head and the surface to be coated is too large, resulting in increased...

Air spraying defects and treatment methods

Air spraying defects and treatment methods In the air spraying technology, there may be a variety of different defects, the causes of these defects and the corresponding treatment methods have many similarities with brush painting. The following are some types of defects related to air spraying technology, causes and treatment methods: Stream suspension: Causes Uneven spraying pressure. The spraying distance is too close. The spraying speed is not balanced with the amount of paint produced. Excessive spraying. The spray Angle is incorrect. The spraying environment temperature is too...

Principle, application and main points of operation of Lovipen colorimeter

Lovipen colorimeter is a color measuring tool widely used in many industries, especially in the field of oil production and trade. The instrument originated from the British company Lovipen, Lovipen colorimeter plays an important role in the field of color measurement. Understanding the nuances of its principle, application, and color perception can greatly improve its effectiveness in various industrial applications.   Working principle The core working principle of Lovipen colorimeter is color contrast. It uses white light as a light source, covering all...

Determination of high speed mechanical stability of latex

As an important basic raw material in industrial production, latex plays a vital role in the production of many products. However, in order to ensure its quality and stability, it is necessary to use a latex high-speed mechanical stability tester. The instrument conforms to the standard requirements of "GBT 8301 concentrated natural latex mechanical stability determination" and "SHT 1151 synthetic latex high speed mechanical stability determination method", and is one of the key equipment necessary for latex production units and...

ASTM G178-2016 Standard Practice for Determination of Material Activation Spectra (Sensitivity to Exposed Source Wavelength) Using Long Pass Filters or Spectroscopic Techniques

Meaning and use 4.1 Activation spectrum identification of the spectral regions of specific exposure sources used, which may be the primary cause of changes in the appearance and/or physical properties of the material. 4.2 Spectroscopic techniques use a prism or grating spectrometer to determine the effect on the material of an isolated narrow spectral band of a light source, each band in the absence of other wavelengths. 4.3 The sharp-cut filter technique uses a specially designed set of sharp-cut UV/visible transmission glass filters...

ASTM G179-2019 Standard Specification for Metal Black and White Panel Temperature Equipment for Natural Climate Testing

Radius 1.1 This specification provides specific information for the manufacture and use of metal black and white panel temperature devices to measure temperatures to estimate the maximum (black) and minimum maximum (white) temperatures of coated metal specimens during natural aging tests. 1.1.1 The structure of a black or white panel has a significant effect on the indicated temperature. This standard describes the robust construction of the panels studied, which has been shown to provide the highest, most consistent temperatures compared to other...