ASTM B489-2018 Standard Practice for Ductility Bending Tests for ElectroDeposition of Metals and Autocatalytic Deposition of Metal Coatings

Meaning and use 4.1 Conventional measurements of the ductility of metal coatings by electrodeposition and autocatalytic deposition can be used for process control, especially when the plating process is used for decorative and engineering purposes. ASTM B489-2018 Standard Practice for Ductility Bending Tests for ElectroDeposition of Metals and Autocatalytic Deposition of Metal Coatings Step 1: Scope 1.1 This practice includes test procedures for determining the ductility of electrodeposited and autocatalytic deposited coatings on sheet or strip base metals. The purpose of this test is...

ASTM B487-2013 Standard Test Method for Measuring the Thickness of Metal and Oxide Coatings by Cross Section Microscopy

Meaning and use 4.1 The thickness of the coating is an important factor in the performance of the coating in use and is usually specified in the coating specification. 4.2 This method is applicable to acceptance testing. ASTM B487-2013 Standard Test Method for Measuring the Thickness of Metal and Oxide Coatings by Cross Section Microscopy Step 1: Scope 1.1 The test method includes the use of an optical microscope to measure the local thickness of the metal and oxide coating by examining the cross section...

ASTM B380-2018 Standard Test Method for Corrosion Testing of Decorative Electrodeposited Coatings by the Corrodkote Method

ASTM B380 Standard test method for Corrosion testing of Decorative electrodeposited Coatings with the Corrodkote Method includes the Corrodkote 2 Method for Evaluating the Corrosion properties of copper/nickel/chromium and nickel/chromium coatings electrodeposited on steel, zinc alloys, aluminum alloys, plastics, and other substrates. Meaning and use 4.1 Nickel/chromium and copper/nickel/chromium electrodeposited coatings are widely used in decorative and protective applications. The Corrodkote test provides a method for controlling the quality of electroplated products and is suitable for manufacturing control as well as research...

What is the glass transition temperature? What instruments are used to measure

Recently, many customers will ask what instrument can measure the glass transition temperature, this term may not be understood by many people, but people engaged in the dsc instrument industry are very familiar with the glass transition temperature, and often use dsc (differential scanning calorimeter) to test the glass transition temperature of different materials. Through the test map and data for material analysis, especially scientific research institutes, university laboratories and plastics, pipes and other enterprises, often use dsc thermal analysis...

Take a look at these technical features of the oxidation induction phase analyzer

The oxidation induction period analyzer adopts a heat-inert miniaturized heating furnace, which can ensure the linear temperature rise of the sample from room temperature. The temperature rise control adopts the PID algorithm of microcomputer software, which is more accurate than the PID control system of hardware. Automatic oxidation induction period after the end of the operation of the instrument buzzes, the process does not need personnel care, simple and efficient. The oxidation induction period analyzer can easily and quickly measure the...

Principle and structure of differential thermal analyzer

Differential thermal analyzer is a thermal analytical instrument that tests the thermal effect of substances in the process of heating or cooling, which can study the relationship between the physical and chemical change rate of substances and temperature, as well as the characteristics of some physical and chemical properties of substances under the action of thermal energy. The functional relationship between the temperature difference and the temperature between the substance and the reference substance can also be measured under the...

The plate method thermal conductivity meter is a test tool for developing and researching materials with low thermal conductivity

The plate method thermal conductivity meter has many advantages such as large area test sample, multiple types (single material or composite material) test material, high precision temperature control, reliable and stable performance, high degree of control automation, easy operation and so on. The thermal conductivity test principle of the plate method is an absolute measurement method and does not require any calibration standards. The instrument is produced according to relevant standards, the test is accurate, the operation is simple, is...

ASTM D4060-0 “Standard Test Method for Determining the Wear Resistance of Organic Coatings using Tabor Abrasion Tester”

ASTM D4060 tests the wear resistance of organic coatings with a Taber grinder. This type of test method was introduced around the 1930s to perform accelerated wear tests. Its simplicity and effectiveness make the device widely used in multiple test protocols and specifications for a wide variety of products around the world. The test performed according to ASTM D4060 involves mounting a flat sample onto a turntable that rotates horizontally at a fixed speed. The two arms are then lowered, each...